HomeMy WebLinkAboutCHICK-FIL-A 1331 FLAMMANG DR O W 4�, INVOICE DATE DUE DATE INVOICE# TOTAL DUE
07/15/2026 08/19/2026 2027-00000003 $200.00
Z 0.. j` 1,O
• •I. II III illlii •
T- T O
63s 7110\7�
Customer#: 23044 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
CHICK-FIL-A 715 Mulberry St
1331 FLAMMANG DR WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 1331 FLAMMANG DR- FOR BILLING INQUIRY: (319)291-4323
07/10/2026
Description Total Price
REINSPECTION 3 $200.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23044 07/15/2026 08/19/2026 2027-00000003 $200.00
Less Prepayment $0.00
Total Due —* $200.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
�,,�•t` Waterloo Fire Rescue
S►,;l Inspection Report 425 E.3rd Street
Chick-Fil-A-1331 Flammang DR,BLDG 1331 Flammang Dr,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type /`� M Inspection Number
07/1012026 Annual Inspection(1Yr) L REINSPECTION) J'�]V7 1 4C? � ,f 21024-R4
Lead Inspector Shift Station Unit
BRAD BALDWIN NIA NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 5
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 0811012026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-0711012026 @ 14:05
$200 re-inspection fee for failure to complete corrections on scheduled 7110126 re-inspection.Complete corrections to avoid fees at following inspections.
BRAD BALDWIN-06105/2026 @ 07:45
Exit/Egress report 2026
BRAD BALDWIN-0610512026 @ 07:45
Withholding re-inspection fee due to progress on 4/9/26
BRAD BALDWIN-0610512026 @ 07:45
S80 annual inspection fee
BRAD BALDWIN-06/0512026 @ 07:45
•Commercial Fire Inspector—brad.baldwin@waterloo-ia.org—Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-06105/2026 @ 07:45
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday—Friday,9:00 a.m.—4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-06105/2026 @ 07:45
$100 re-inspection fee,failure to complete corrections as of 5/6126.Complete corrections to avoid possible fees at following inspections.
BRAD BALDWIN-0610512026 @ 07:45
$150 re-inspection fee for failure to complete corrections on scheduled 615/26 inspection.Complete corrections to avoid fees at following inspections
SIGNATURES
Contact signature Inspector signature
GENERATED ON 7/10/26, 2:OE PM 1 OF 5
No signature
Report completed post inspection
Ben Nanda 2026 Date: BRAD BALDWIN 0711012026
CHECKLISTS
GENERATED ON 7/10/26, 2:08 PM 2 OF 5
Reinspection
Stau;s Code Description
Fail 2015 IPMC 704.1.1-Automatic sprinkler systems
Inspection,testing and maintenance of automatic sprinkler Location:Sprinkler 5 year inspection
systems shall be in accordance with NFPA 25. Comments:Provide required inspection with report of contractor's
inspection uploaded to Compliance Engine including any
deficiencies corrected.Currently 644 days past due.
Additional comments:Report uploaded to Compliance Engine
currently 786 days past due as of 7110126.Contractor shall complete
inspection and upload report.
Fail 5.2.1-Annual sprinkler system inspection
Sprinklers shall be inspected at least annually by licensed Location:Sprinkler system
contractor Comments:Provide required annual inspection and report including
any deficiencies corrected to be uploaded by contractor to
Compliance Engine.Currently 2125 days past due.
Additional comments:Deficiencies still remain on Compliance
Engine on 7110126
MIMI
Fail 603.1.1-Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment, Location:West exterior electric panel
wiring,devices and appliances shall be tested;and listed by Comments:Replace broken panel cover latch,currently unable to
an approved agency and labeled;and installed,used and open and access panel.
maintained in accordance with NFPA 70 and all instructions
included as part of such listing. Additional comments:Did not review on 7110/26 inspection,will re-
inspect at later date.
i
,, , , : . :
t . . .
„t:::
r.
4
GENERATED ON 7/10/25, 2:08 PM 3 OF 5
Fail 903.3.1.1-NFPA 13 sprinkler systems.
Where the provisions of this code require that a building or Location:Sprinkler riser room
portion thereof be equipped throughout with an automatic Comments:Water softener equipment obstructing sprinkler riser and
sprinkler system in accordance with this section,sprinklers valves shall be corrected.
shall be installed throughout in accordance with NFPA 13
except as provided in Sections 903.3.1.1.1 and 903.3.1.1.2.
I.
l 01 al
eon
•
r 1
lt"'•:
•
1-11
Fail Chapter 14-Inspection,testing,and maintenance
Fire alarm system tested at least annually by licensed Location:Fire alarm
contractor Comments:Provide required annual inspection and report including
any deficiencies corrected to be uploaded by contractor to
Compliance Engine.Currently 2125 days past due.
Additional comments:Deficiency still remains on Compliance Engine
as of 7/10/26.
moo
GENERATED ON 7/10/26, 2:06 PM 4 OF 5
'® Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $200.00
Invoice Number Check Number Transaction Number
NIA •
NIA NIA
5OF 5
GENERATED ON 7/10/28, 2:08 PM