Loading...
HomeMy WebLinkAboutKWIK STAR #569 875 FISHER DR OF WA 7.4•• INVOICE DATE DUE DATE INVOICE# TOTAL DUE to 07/15/2026 08/19/2026 2027-00000010 $80.00 • • 1 II mum. • *- T 0 0 7 t/17% Customer#: 23710 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KWIK STAR- FISHER DR 715 Mulberry St 875 FISHER DR WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 875 FISHER DR-07/06/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23710 07/15/2026 08/19/2026 2027-00000010 $80.00 Less Prepayment $0.00 Total Due -+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 4 Inspection Report 425 E.3rd Street Kwik Star-875 Fisher DR,BLDG 875 Fisher Dr,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0710612026 Annual Inspection(1Yr) /0 ��/- 17404 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 42 0 15 @ 27 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/03/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07/0612026 @ 15:10 •$80 annual inspection fee BRAD BALDWIN-0710612026 @ 15:10 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-0710612026 @ 15:10 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07/0612026 @ 15:10 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0710912026 @ 08:11 Fire Marshall Weliver approved the storage of fueled equipment(power washer,snow blower)in"Utility Room/Water Softener Room".Equipment shall maintained proper clearances from fuel fired appliances and all combustibles. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection Alicia 2025-store leader Date: BRAD BALDWIN 07/09/2026 CHECKLISTS GENERATED ON 7/9/26, 8:17 AM 1 OF 7 Means of Egress S.a Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Utility room-East exit door The force for pushing or pulling open interior swinging Comments:Repair or replace door to open with less than 15lbs of egress doors,other than fire doors,shall not exceed 5 force.Replacement of door requires permit obtained and inspection. pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected toa 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:LWhere door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. GENERATED ON 7/9/26, 8:17 AM 2 OF 7 Additional Codes Code Description Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Roof permit with the International Building Code,and any alterations, Comments:Contractor shall obtain inspection of work when additions,changes in use or changes in structures required complete,currently work in progress. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Electric permit-Carwash with the International Building Code,and any alterations, Comments:Contractor(Tatroe Electric)shall obtain inspection when additions,changes in use or changes in structures required work complete, by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 2303.2-Emergency disconnect switches. An approved emergency disconnect switch shall be provided Location:Behind register counter at an approved location to stop the transfer of fuel to the fuel Comments:Provide identifying signage in approved location for dispensers in the event of a fuel spill or other emergency.The disconnect switch. emergency disconnect switch for exterior fuel dispensers shall be provided with ready access and shall be located within 100 feet(30 480 mm)of,but not less than 20 feet(6096 mm)from,the fuel dispensers.For interior fuel-dispensing operations,the emergency disconnect switch shall be provided with ready access and be installed at an approved location.Such devices shall be distinctly labeled as: "EMERGENCY FUEL SHUTOFF."Signs shall be provided in approved locations. Fail 2305.2-Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump station#5 in proper working order at all times in accordance with Comments:91 octane fuel pump currently out of service.Repairs Sections 2305.2.1 through 2305.2.5. shall be made to operate in proper working order. Fail 2305.2-Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump station#10 in proper working order at all times in accordance with Comments:87 octane fuel pump currently out of service.Repairs Sections 2305.2.1 through 2305.2.5. shall be made to operate in proper working order. Fail 2305.2-Equipment maintenance and inspection. OMotor fuel-dispensing facility equipment shall be maintained Location:Fuel pump station#13 in proper working order at all times in accordance with Comments:All fuel pumps currently out of service.Repairs shall be Sections 2305.2.1 through 2305.2.5. made to operate in proper working order. Fail 313.1-General. 0 Fueled equipment including,but not limited to,motorcycles, mopeds,lawn-care equipment,portable generators and portable cooking equipment,shall not be stored,operated or repaired within a building.Exceptions:1.Buildings or rooms constructed for such use in accordance with the International Building Code.2.Where allowed by Section 314.3.Storage of equipment utilized for maintenance purposes is allowed in approved locations where the aggregate fuel capacity of the stored equipment does not exceed 10 gallons(38 L)and the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. GENERATED ON 7/9/26, 8:17 AM 3 OF 7 Emergency Equipment Star Description Fail 1203.2.15-Means of egress illumination. C Emergency power shall be provided for means of egress Location:Front exit illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Car wash-mechanical room illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Above windshield wiper fluid shelving illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights,lights very dim when tested. General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container for disposal of oily rags.Provide of such containers shall be removed and disposed of daily. documentation of disposable wipes being used to inspector as possible alternative,will verify with Fire Marshall if approved. GENERATED ON 7/9/26, 8:17 AN 4 OF 7 Electrical Safety S;atos code Description Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Kitchen equipment shall be provided in accordance with Section Comments:Remove obstructions(including paperwork magnetized 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or to panel)to clear view of electric panels,maintain proper clearances less,and Section 110.33 of NFPA 70 for electrical equipment at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Aiwa nIrth 3054,5__ uii J t,-� 5 OF GENERATED ON 7/9/26, 9:17 AM Portable Fire Extingusihers Stz:�= Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Car wash maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguishers(2),currently Exceptions:1.The distance of travel to reach an extinguisher past due. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Utility room-Near water softeners maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,currently past Exceptions:1.The distance of travel to reach an extinguisher due since June 2026 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 7/9/26, 8:17 AM 6 OF 7 Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/8/26, 8:17 MI 7 OF 7