Loading...
HomeMy WebLinkAboutSIDECAR COFFEE 1850 W. RIDGEWAY AVE of W4 TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE i 0 07/15/2026 08/19/2026 2027-00000017 $80.00 u /A o • '� I ■ II III IIIO • > T-w T 0 s 'VI', Customer#: 24039 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SIDECAR COFFEE 715 Mulberry St 1850 W RIDGEWAY AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-1850 W RIDGEWAY AVE#7- FOR BILLING INQUIRY: (319)291-4323 07/07/2026 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24039 07/15/2026 08/19/2026 2027-00000017 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue ' Inspection Report ���Y' 425 E.3rd Street Sidecar Coffee-1850 W Ridgeway AVE,BLDG 1850 W Ridgeway Ave-STE 7, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type J Inspection Number 0710712026 Annual Inspection(1Yr) a'-f'0q 4 11583 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 040 08 Q26 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0811012026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07107/2026 @ 13:53 •$80 annual inspection fee BRAD BALDWIN-07I07/2026 @ 13:53 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/0712026 @ 13:53 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-07107/2026 @ 14:00 Fire extinguisher due annually serviced September 2026. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Andy Fuchtman Date: BRAD BALDWIN 07/07/2026 CHECKLISTS 1 OF 5 GENERATED ON 7/7/26, 2:09 PM Emergency Equipment Status Code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Front exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and egress lights combo that the required load for a duration of not less than 90 minutes. failed to illuminate during test. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Back exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and egress lights combo that the required load for a duration of not less than 90 minutes. failed to illuminate during test. General Housekeeping Status Code Description Fail 315.3.1-Ceiling clearance. Storage shall be maintained 2 feet(610 mm)or more below Location:Storage closet the ceiling in nonsprinklered areas of buildings or not less than 18 inches(457 mm)below sprinkler head deflectors in Comments:Remove storage within 18"below sprinkler head. sprinklered areas of buildings.Exceptions:1.The 2-foot(610 mm)ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings.2.The 18-inch(457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1,903.3.1.2 or 903.3.1.3. Fire Sprinkler System S.:Cur Code Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Sprinkler system obstructions that will delay activation or obstruct the water Comments:Several sprinkler heads noted with dust/debris,carefully distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being clean all debris from heads. used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. OENEPATED ON 7/7/26, 2:06 PM 2 OF 5 Electrical Safety S'e ,s Code Description Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Mechanical room equipment shall be provided in accordance with Section Comments:Remove all storage within 36"from electric panels. 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Maintain proper clearances at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Il4.¢- .--- - i I e S e' —3' } 0 1 i • y 'kg • go { A f 1y Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Mechanical room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide approved permanent signage"Electric Room"on ROOM"or similar approved wording.The disconnecting door for firefighters access,laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Mechanical room ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip hanging by wires next to electric panel shall to environmental or physical damage. be properly mounted to avoid hanging by wires 3 OF 5 GENERATED ON 7/7/26, 2:09 PM Fail 603.6-Extension cords. Ox Extension cords and flexible cordsshall not be a substitute Location:Front wall of store-Speaker near ceiling for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible Comments:Flexible wiring shall not extend through concealed space (above drop ceiling).Remove white cord to speaker from ceiling cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, space.Exception:Low voltage wiring nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 7/7/26, 2:09 PM 4 OF 5 Eo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number N/A N/A N/A GENERATED ON 7/7/26, 2:e9 PM 5 OF 5