COMMERCIAL FIRE INSPECTION- 325 FRANKLILN ST-06/26/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24987 07/15/2026 08/19/2026 2027-00000021 $80.00
Less Prepayment $0.00
Total Due-* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
•
/ G(en co
/Ur d 8an3aSit
3 Pzi.
t Waterloo Fire Rescue ` r(Js V; I I /v // (a- 4',h
dO ► Inspection Report ge/W
425 E.3rd Street
Vape Time Smoke Shop-325 Franklin ST,BLDG 325 Franklin St,Waterloo IA 50703
INSPECTION DETAILS •
Inspection Date Inspection Type Inspection Number
0612612026 Annual Inspection(1Yr) a T 18111 �' R)•,� 23042
Lead Inspector Shift Station Unit
BRAD BALDWIN NIA NIA NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 27 0 13 ® 39
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 07/3012026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-06/29/2026 @ 11:55
•$80 annual inspection fee
BRAD BALDWIN-0612912026 @ 11:55
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-0612912026 @ 11:55
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completedeelpost ostinspection
Mohammed Farooq-2026 Date: BRAD BALDWIN 06/30/2026
CHECKLISTS
GENERATED ON 6/30/26, 6:37 AM 1 OF 8
Additional Codes
S.a:us Code Description
Fail 1010.2.4-Locks and latches.
Locks and latches shall be permitted to prevent operation of Location:Front exit door
doors where any of the following exist:1.Places of detention Comments:Permanent approved signage shall be installed on door
or restraint.2.In Group I-1,Condition 2 and Group 1-2 stating,"THIS DOOR SHALL REMAIN UNLOCKED DURING
occupancies where the clinical needs of persons receiving BUSINESS HOURS"
care require containment or where persons receiving care
pose a security threat,provided that all clinical staff can
readily unlock doors at all times,and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space.
GENERATED ON 6/30/26, 6:37 AM 2 OF 8
Fail 1010.2.4-Locks and latches.
Locks and latches shall be permitted to prevent operation of Location:Back exit door
doors where any of the following exist:1.Places of detention Comments:Exit door not allowed more than(1)single motion to
or restraint.2.In Group I-i,Condition 2 and Group 1-2 unlock and unlatch door,currently have twist knob and deadbolt
occupancies where the clinical needs of persons receiving hardware installed.Hardware shall be changed to comply with code.
care require containment or where persons receiving care
pose a security threat,provided that all clinical staff can
readily unlock doors at all times,and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space.
GENERATED ON 6/30/26, 6:37 AM 3 OF 8
Fail 102.3-Change of use or occupancy.
A change of occupancy shall not be made unless the use or Location:Storage room
occupancy is made to comply with the requirements of this Comments:Blanket covering bubble wrap noted during 6126126
code and the International Existing Building Code. inspection:Remove all uses of bedding immediately.
Exception:Where approved by the fire code official,a change
of occupancy shall be permitted without complying with the
requirements of this code and the International Existing
Building Code,provided that the new or proposed use or
occupancy is less hazardous,based on life and fire risk,than
the existing use or occupancy.
ra :.
,e
•
` gib
Emergency Equipment
code Description
Fail 1203.2.6-Exit signs.
Emergency power shall be provided for exit signs as required Location:Front exit
in Section 1013.6.3.The system shall be capable of powering
Comments:Repair or replace exit sign and lights that failed to
the required load for a duration of not less than 90 minutes. illuminate during test.
Fail 1203.2.6-Exit signs.
Emergency power shall be provided for exit signs as required Location:Back exit
in Section 1013.6.3.The system shall be capable of powering
Comments:Repair or replace exit sign that failed to illuminated
the required load for a duration of not less than 90 minutes. during test
GENERATED ON 6/30/26, 6:37 AM 4 OF 8
Electrical Safety
Status Code Description
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Storage room
Identified electrical hazards shall be abated.Identified Comments:Repair loose outlet in box below table(east wall).
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:Storage room
prohibited.Approved covers shall be provided for all switch Comments:Replace missing(2)outlet covers.
and electrical outlet boxes.
Fail 603.4-Working space and clearancesclearance.
A working space of not Working space around electrical Location:Mechanical room
equipment shall be provided in accordance with Section Comments:Remove all storage obstructing access to electric panel
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or and maintain 36"clearance from furnace and panel at all times.
less,and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts.The minimum required working space
shall be not less than 30 inches(762 mm)in width,36 inches
(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the
electrical service equipment is wider than 30 inches(762
mm),the minimum working space shall be not less than the
width of the equipment.Storage of materials shall not be
located within the designated working space.Exceptions:1.
Where other dimensions are required or allowed by NFPA 70.
2.Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches(559 mm)by 30
inches(762 mm).
Fail 603.5.2-Application and usePower supply.
Relocatable power taps and current taps shall be directly Location:Below register counter
connected to a permanently installed receptacle.Exceptions: Comments:Each power strip shall plug directly to a permanent
1.Where approved for use in a Group A occupancy or in a
outlet,remove all power strips daisy chained.
meeting room in a Group B occupancy,not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment.2.Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
GENERATED ON 6/30/26, 6:37 AM 5 OF 8
Fail 603.5.3-Installation.
ORelocatable power tap cords shall not extend through walls, Location:Mechanical room
ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly mounted to avoid hanging
to environmental or physical damage. by wires
t
j
a
Nam-
, ,. ..".4 , * ,t:-
� /
Fail 603.5.3-Installation.
(J Relocatable power tap cords shall not extend through walls, Location:Behind register counter
ceilings,floors,under doors or floor coverings,or be subject Comments:Flexible cords installed in walk ways shall be protected
to environmental or physical damage. by a listed cord protector(see attached)to avoid damage to cord
hazard.Multi-plug adapter shall also comply with NFPA 70 standards.
fX
0 CV .'),. .414. , •
A. tRi
rr
\ ' a
4
GENERATED ON 6/30/26, 6:37 AM 6 OF 8
Fail 603.6-Extension cords.
OExtension cords and flexible cordsshall not be a substitute Location:Below bong shelving
for permanent wiring and shall be listed and labeled in Comments:Install missing outlet cover and remove brown extension
accordance with UL 817.Extension cords and flexible cord to LED lighting.
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
Gx Portable fire extinguishers shall be selected,installed and Comments:Provide annual service to extinguisher.Last recorded
maintained in accordance with this section and NFPA 10. service in 2014.Extinguishers shall be new or serviced annually.
Exceptions:1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.