Loading...
HomeMy WebLinkAboutVAPE TIME CEDAR FALLS, INC. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 WAIF ���! 07/15/2026 08/19/2026 2027-00000021 $80.00 sk (J tI f • U �lflll 1 I • o a3S7tl1st Customer#: 24987 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ABID BANGUSH VAPE TIME CEDAR FALLS INC 715 Mulberry St 31 GLENGBROOK ROAD WATERLOO, IA 50703 HICKSVILLE,NY 11801-4836 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 325 FRANKLILN ST-06/26/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24987 07/15/2026 08/19/2026 2027-00000021 $80.00 Less Prepayment $0.00 Total Due-* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. • / G(en co /Ur d 8an3aSit 3 Pzi. t Waterloo Fire Rescue ` r(Js V; I I /v // (a- 4',h dO ► Inspection Report ge/W 425 E.3rd Street Vape Time Smoke Shop-325 Franklin ST,BLDG 325 Franklin St,Waterloo IA 50703 INSPECTION DETAILS • Inspection Date Inspection Type Inspection Number 0612612026 Annual Inspection(1Yr) a T 18111 �' R)•,� 23042 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 27 0 13 ® 39 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/3012026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06/29/2026 @ 11:55 •$80 annual inspection fee BRAD BALDWIN-0612912026 @ 11:55 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-0612912026 @ 11:55 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost ostinspection Mohammed Farooq-2026 Date: BRAD BALDWIN 06/30/2026 CHECKLISTS GENERATED ON 6/30/26, 6:37 AM 1 OF 8 Additional Codes S.a:us Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Front exit door doors where any of the following exist:1.Places of detention Comments:Permanent approved signage shall be installed on door or restraint.2.In Group I-1,Condition 2 and Group 1-2 stating,"THIS DOOR SHALL REMAIN UNLOCKED DURING occupancies where the clinical needs of persons receiving BUSINESS HOURS" care require containment or where persons receiving care pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 6/30/26, 6:37 AM 2 OF 8 Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Back exit door doors where any of the following exist:1.Places of detention Comments:Exit door not allowed more than(1)single motion to or restraint.2.In Group I-i,Condition 2 and Group 1-2 unlock and unlatch door,currently have twist knob and deadbolt occupancies where the clinical needs of persons receiving hardware installed.Hardware shall be changed to comply with code. care require containment or where persons receiving care pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 6/30/26, 6:37 AM 3 OF 8 Fail 102.3-Change of use or occupancy. A change of occupancy shall not be made unless the use or Location:Storage room occupancy is made to comply with the requirements of this Comments:Blanket covering bubble wrap noted during 6126126 code and the International Existing Building Code. inspection:Remove all uses of bedding immediately. Exception:Where approved by the fire code official,a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code,provided that the new or proposed use or occupancy is less hazardous,based on life and fire risk,than the existing use or occupancy. ra :. ,e • ` gib Emergency Equipment code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Front exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and lights that failed to the required load for a duration of not less than 90 minutes. illuminate during test. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Back exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminated the required load for a duration of not less than 90 minutes. during test GENERATED ON 6/30/26, 6:37 AM 4 OF 8 Electrical Safety Status Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Storage room Identified electrical hazards shall be abated.Identified Comments:Repair loose outlet in box below table(east wall). hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Storage room prohibited.Approved covers shall be provided for all switch Comments:Replace missing(2)outlet covers. and electrical outlet boxes. Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Mechanical room equipment shall be provided in accordance with Section Comments:Remove all storage obstructing access to electric panel 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or and maintain 36"clearance from furnace and panel at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Below register counter connected to a permanently installed receptacle.Exceptions: Comments:Each power strip shall plug directly to a permanent 1.Where approved for use in a Group A occupancy or in a outlet,remove all power strips daisy chained. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 6/30/26, 6:37 AM 5 OF 8 Fail 603.5.3-Installation. ORelocatable power tap cords shall not extend through walls, Location:Mechanical room ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly mounted to avoid hanging to environmental or physical damage. by wires t j a Nam- , ,. ..".4 , * ,t:- � / Fail 603.5.3-Installation. (J Relocatable power tap cords shall not extend through walls, Location:Behind register counter ceilings,floors,under doors or floor coverings,or be subject Comments:Flexible cords installed in walk ways shall be protected to environmental or physical damage. by a listed cord protector(see attached)to avoid damage to cord hazard.Multi-plug adapter shall also comply with NFPA 70 standards. fX 0 CV .'),. .414. , • A. tRi rr \ ' a 4 GENERATED ON 6/30/26, 6:37 AM 6 OF 8 Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Below bong shelving for permanent wiring and shall be listed and labeled in Comments:Install missing outlet cover and remove brown extension accordance with UL 817.Extension cords and flexible cord to LED lighting. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Gx Portable fire extinguishers shall be selected,installed and Comments:Provide annual service to extinguisher.Last recorded maintained in accordance with this section and NFPA 10. service in 2014.Extinguishers shall be new or serviced annually. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 6/30/26, 6:37 AM 7 OF 8 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/36/26,8:37 AAI a OF e