Loading...
HomeMy WebLinkAboutPLACO SMOKE & VAPE 1010 E. MITCHELL AV STE 8 W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE O > ,' 4 � �� 07/15/2026 08/19/2026 2027-00000015 $80.00 u r O • 'III II II II II • T--=-� O 7V11‘ Customer#: 24993 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PLACO SMOKE& VAPE 715 Mulberry St 1010 MITCHELL AVENUE WATERLOO, IA 50703 STE 8 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-1010 E MITCHELL AV#8- FOR BILLING INQUIRY: (319)291-4323 07/08/20 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24993 07/15/2026 08/19/2026 2027-00000015 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report d���`.� 425 E.3rd Street " . Placo Smoke&Vape-1010 E Mitchell AVE,BLDG 1010 E Mitchell Ave-STE 8, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07/08/2026 Annual Inspection(1Yr) . 241 96/Z $e6 CD 23187 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 029 G8 ® 38 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/10/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07/13/2026 @ 08:52 •$80 annual inspection fee BRAD BALDWIN-0711312026 @ 08:52 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/13/2026©08:52 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Sulejman Placo(2026) Date: BRAD BALDWIN 07113/2026 CHECKLISTS GENERATED ON 7/13/26, 8:55 AM 1 OF 7 Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Basement illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light near stairs. Fail 1203,2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Back exit in Section 1013.6.3.The system shall be capable of powering Comments:Required exits shall include no more than one single the required load for a duration of not less than 90 minutes. motion to unlock and unlatch door.Options:(1)Door hardware shall comply with required exit codes,prohibited locks shall be removed. (2)Per occupancy,second exit not required,would approve exit sign to be covered or removed by capping electrical wires and containing in box with cover.Current lock hardware would be approved to remain if exit sign removed. GENERATED ON 7/13/26, 8:55 AM 2 OF 7 Electrical Safety Stai,!s Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Near display cases Identified electrical hazards shall be abated.Identified Comments:Flexible wiring installed in a walk path requires a listed hazardous electrical conditions in permanent wiring shall be cord protector provided to avoid the hazard of cord damage.See brought to the attention of the responsible code official. attachment for example of protector. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 1114 ` WK \`rt 71.' 00. A ki Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Near cigarette shelving Identified electrical hazards shall be abated.Identified Comments:Flexible wiring installed in a walk path requires a listed hazardous electrical conditions in permanent wiring shall be cord protector provided to avoid the hazard of cord damage.See brought to the attention of the responsible code official. attachment for example of protector. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Alr GENERATED ON 7/13/26, 8:55 AM 3 OF 7 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Electric panel-near back door equipment shall be provided in accordance with Section Comments:Remove storage obstructing access to electric panel. 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Maintain 36"clearance and clear access to panel at all times less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Mini fridge in back area for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to mini fridge,appliance accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through shall plug directly to wall outlet. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 7/13/26, 8:55 AM 4 OF 7 Portable Fire Extingusihers Status Code Description Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Basement following locations:1.In new and existing Group A,B,E,F,H, Comments:Provide(1)properly serviced 2A:20B:C extinguisher in I,M,R-1,R-2,R-4 and S occupancies.Exceptions:i.ln Group basement.Extinguisher shall be properly mounted on wall bracket R-2 occupancies,portable fire extinguishers shall be required between flinches-5ft from the floor in height. only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 7/13/26, 8:55 AM 5 OF 7 Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:All extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguishers,last recorded Exceptions:1,The distance of travel to reach an extinguisher service in September 2024. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 7/13/26, 8:55 AM 6 OF 7 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/13/28, 8:55 AM 7 OF 7