Loading...
HomeMy WebLinkAboutTITAN PROPERTY INVESTMENTS 200 LAFAYETTE ST OF W A . INVOICE DATE DUE DATE INVOICE# TOTAL DUE �� 07/16/2026 08/20/2026 2027-00000015 $50.00 fA �� !!/ll��r • •it l i • ilia *- T A:*s 12> 7v11N- Customer#: 23718 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable TITAN PROPERTY INVESTMENTS 715 Mulberry St 699 WALNUT ST WATERLOO, IA 50703 DES MOINES,IA 50309 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL PROP INSPECTION- 200 LAFAYETTE ST#2-07/13/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23718 07/16/2026 08/20/2026 2027-00000015 $50.00 Less Prepayment $0.00 Total Due —* $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue A.N:4 Inspection Report p 425 E.3rd Street Unit#2-200 Lafayette ST,BLDG 200 Lafayette Street-STE Unit#2,Waterloo IA 50703-4629 INSPECTION DETAILS Inspection Date Inspection Type j� Inspection Number tion 0711312026 2015 IPMC Rental Inspec REINSPECTION a ! `����" 22804-R1 Lead Inspector Shift Station Unit NATE BEUSELING NIA N/A NIA Other Inspectors N/A SUMMARY OF INSPECTION 00 04 018 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your inspection to: Reinspection Date NATE BEUSELING 0811212026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-0611112026 @ 07:52 Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605 NATE BEUSELING-0611112026 @ 07:52 Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. NATE BEUSELING-06/1112026 @ 07:52 At time of inspection all 5 units in this property was not registered with the city as rentals there will be a 100.00 fee applied to each unit,making it a 500.00 non registration fee NATE BEUSELING-07/13/2026 @ 09:58 At Reinspection Maintenance was there as representative,of the 22 call outs 4 have been completed,50.00 Fee assessed and reinspection date reset 30 days SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alf° IfiliO TITAN PROPERTY INVESTMENTS LLC Date: NATE BEUSELING 07/13/2026 GENERATED ON 7/13/26, 10:06 AM 1 OF 9 CHECKLISTS GENERATED ON 7/13/26, 10:06 AM 2 OF 9 Reinspection Status Cody: Description Fail 2015 IPMC 108.1.1-Unsafe structures Unsafe structures.An unsafe structure is one that is found to Location:Garage on Property be dangerous to the life,health,property or safety of the Comments:Garage on property has collapsed roof damaged walls public or the occupants of the structure by not providing and is not in a safe state shall be removed as soon as possible with minimum safeguards to protect or warn occupants in the Correct Demo permits event of fire,or because such structure contains unsafe equipment or is so damaged,decayed,dilapidated, structurally unsafe or of such faulty construction or unstable foundation,that partial or complete collapse is possible. Fail 2015 IPMC 304.13-Window,skylight and door frames Every window,skylight,door and frame shall be kept in Location:Living room sound condition,good repair and weather tight. Comments:Windows are not weather tight,Repair or replace windows and any frame repair required utilizing permits and inspections Fail 2015 IPMC 304.13-Window,skylight and door frames Every window,skylight,door and frame shall be kept in Location:Kitchen sound condition,good repair and weather tight. Comments:Window shall be repaired to original function,open,shut and stay open Fail 2015 IPMC 304.18-Building security Doors,windows or hatchways for dwelling units,room units Location:Front door of unit or housekeeping units shall be provided with devices Comments:Door frame and door shall be able to shut and latch designed to provide security for the occupants and property without having to dead bolt the door,currently door has to be locked within. to remain latched due to door frame Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Living room maintained in good,clean and sanitary condition.Peeling, Comments:Carpet wet/mitigate cause and repair or replace chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Living room maintained in good,clean and sanitary condition.Peeling, Comments:All Drywall damage in living room and softness around chipping,flaking or abraded paint shall be repaired,removed windows from leaking windows shall be repaired or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. GENERATED ON 7/13/26, 10:06 AM 3 OF 9 Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Living room maintained in good,clean and sanitary condition.Peeling, Comments:All door and window trim shall be repaired or replaced chipping,flaking or abraded paint shall be repaired,removed and tight to walls or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. li / I Y i w Illt • S 3 Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Kitchen maintained in good,clean and sanitary condition.Peeling, Comments:Kitchen cabinets missing doors shall be replaced chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. GENERATED ON 7/13/26, 10:06 AM 4 OF 9 Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Bathroom maintained in good,clean and sanitary condition.Peeling, Comments:Drywall around shower soft,shall be investigated for chipping,flaking or abraded paint shall be repaired,removed leaks and repaired,also drywall or covered.Cracked or loose plaster,decayed wood and p around water line to toilet in disrepair shall be secured other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3-Interior surfaces QInterior surfaces,including windows and doors,shall be Location:Bathroom maintained in good,clean and sanitary condition.Peeling, Comments:Moisture chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 309.1-Infestation Structures shall be kept free from insect and rodent Location:Unit 2 infestation.Structures in which insects or rodents are found Comments:Mice and cockroaches observed in unit,will need a shall be promptly exterminated by approved processes that licensed contractor to perform pest control and a copy of pest will not be injurious to human health.After pest elimination, control agreement to close out proper precautions shall be taken to prevent reinfestation. Fail 2015 IPMC 505.4-Water heating facilities Water heating facilities shall be properly installed,maintained Location:Basement and capable of providing an adequate amount of water to be Comments:Water heater not to code,have a license contractor pull drawn at every required sink,lavatory,bathtub,shower and permit and bring up to code and have proper Plumbing Inspection laundry facility at a minimum temperature of 110°F(43°C).A gas-burning water heater shall not be located in any bathroom,toilet room,bedroom or other occupied room normally kept closed,unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters • GENERATED ON 7/13/26, 10:06 AM 5 OF 9 Fail 2015 IPMC 605.2-Receptacles Every habitable space in a dwelling shall contain not less Location:living room than two separate and remote receptacle outlets.Every Comments:Outlets loose to wall shall be secured laundry area shall contain not less than one grounding-type receptacle or a receptacle with a ground fault circuit interrupter.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. t 4 Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location Carbon monoxide alarms in dwelling units shall be installed Location:Living room outside of each separate sleeping area in the immediate Comments:No CO detection present shall be added or combo smoke vicinity of the bedrooms.Where a fuel-burning appliance is and CO located within bedroom or its attached bathroom,a carbon monoxide alarm shall be installed within the bedroom. GENERATED ON 7/13/26, 10:06 AM 6 OF 9 Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Common Areas following locations:1.In new and existing Group A,B,E,F,H, Comments:Fire Extinguishers shall be mounted in a correct box in I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group common area between Apartments R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Fail R5-Exterior Structure Is the exterior of the structure maintained in good repair, Location:Property structurally sound and sanitary state?(IPMC 304) Comments:Handrail to back unit on driveway side laying on ground shall be repaired GENERATED ON 7/13/26, 10:06 AM 7 OF 9 Fail R5-Exterior Structure Is the exterior of the structure maintained in good repair, Location:Exterior property structurally sound and sanitary state?(IPMC 304) Comments:Cracks and wear on building shall be repaired ✓i 'ii• '4 I NI Fail R5-Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state?(IPMC 304) GENERATED ON 7/13/28, 10:06 AM 8 OF 9 10 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/13/26, 10:06 AN 9 OF 9