Loading...
HomeMy WebLinkAboutGREENHOUSE KITCHEN 1730 W. RIDGEWAY AV OF W A T4' INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4,! 07/16/2026 08/20/2026 2027-00000025 $80.00 • , T T O 4S 7 v 11‘ Customer#: 23829 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GREENHOUSE KITCHEN 715 Mulberry St PO BOX 708 WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1730 W. RIDGEWAY AVE FOR BILLING INQUIRY: (319)291-4323 #500-7/14/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23829 07/16/2026 08/20/2026 2027-00000025 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue tv Inspection Report ` 425 E.3rd Street Greenhouse Kitchen-1730 W Ridgeway AVE,BLDG 1730 W Ridgeway Ave-STE 500,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07/14/2026 Annual Inspection(1Yr) (cBO"I(� �i�''}`ems 7865 Lead Inspector Shift Station l��/ Unit BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION � 41 CD @26 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08115/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07/16/2026 @ 07:49 •$80 annual inspection fee BRAD BALDWIN-07116/2026 @ 07:49 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07116/2026 @ 07:49 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection Ryan Drewes-2026 Date: BRAD BALDWIN 07/16/2026 CHECKLISTS GENERATED ON 7/16/26, 7:57 AM 1 OF 5 Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. OEmergency power shall be provided for means of egress Location:Above door to bathroom hallway illumination in accordance with Sections 1008.3 and 1104.5.1, Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Dining area illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights(2)on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test.Was not able to access women's bathroom during 7114126 inspection,lights shall be tested and repaired if not functioning properly Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Bathroom hallway illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Ct Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self closing lid for disposal of such containers shall be removed and disposed of daily. of soiled rags(fats,oils or grease).See attachment. g 0: • f GENERATED ON 7/16/26, 7:57 AM 2 OF 5 Fire Service Features Status Code Dscrintion Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Front of building address identification.The address identification shall be Comments:"Suite 500"numbers shall be installed to comply with legible and placed in a position that is visible from the street code requirements.Numbers shall be in contrast with the building or road fronting the property.Address identification and easily visible from the road. characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Electrical Safety Code Description Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Kitchen ceilings,floors,under doors or floor coverings,or be subject Comments:Power stripshall be properly mounted or supported to environmental or physical damage. P P Y to avoid hanging by wires. Fail 603.6-Extension cords. 0 Extension cords and flexible cordsshall not be a substitute Location:Menu TV for permanent wiring and shall be listed and labeled in Comments:TV cord shall not pass through wall.If adding new outlet, accordance with UL 817.Extension cords and flexible licensed electrical contractor shall obtain permit and inspection. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 7/16/26, 7:57 AM 3 OF 5 Portable Fire Extingusihers Status Cale Description Fail 906.2-General requirements. Portable lire extinguishers shall be selected,installed and Location:Extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,currently Exceptions:1.The distance of travel to reach an extinguisher past due for service since Oct 2025. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10,3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. 4 OF 5 GENERATED ON 7/16/28, 7:57 AM `® Statement of Fees FEE p Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA WA NIA 5 OF 5 GENERATED ON 7/16/26, 7:57 AM