Loading...
HomeMy WebLinkAboutICON DONUTS 1730 W. RIDGEWAY AV O F W q pF INVOICE DATE DUE DATE INVOICE# TOTAL DUE f ' ,` 07/16/2026 08/20/2026 2027-00000026 $80.00 o O ,miy.�. /� • •...• m • O 04, 7bi7�� Customer#: 23835 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ICON DONUTS 715 Mulberry St 1730 W RIDGEWAY AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1730 W. RIDGEWAY AVE FOR BILLING INQUIRY: (319)291-4323 #600-7/14/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23835 07/16/2026 08/20/2026 2027-00000026 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue two Inspection Report 425 E.3rd Street P Icon Donuts-1730 W Ridgeway AVE,BLDG 1730 W Ridgeway Ave-STE 600, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type i� n Inspection Number 07/14/2026 Annual Inspection(1Yr) ' f 8316 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 50 0 12 ® 13 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/1712026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07115/2026 @ 08:03 •$80 annual inspection fee BRAD BALDWIN-07/15/2026 @ 08:03 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07115/2026 @ 08:03 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Ryan Drewes-2026 Date: BRAD BALDWIN 07/16/2026 CHECKLISTS Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. 'x Emergency power shall be provided for means of egress Location:Kitchen illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate during test.Also,one of the egress lights currently damaged (hanging by wires)shall be corrected. GENERATED ON 7/16/26, 8:09 AN 1 OF 5 General Housekeeping Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self closing lid for soiled of such containers shall be removed and disposed of daily. rag disposal.Rags containing fats,oils or grease shall be disposed in container and removed from the building daily. Fire Service Features Status Code Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Front of building address identification.The address identification shall be Comments:"Suite 500"numbers shall be installed to comply with legible and placed in a position that is visible from the street code requirements.Numbers shall be in contrast with the building or road fronting the property.Address identification and easily visible from the road. characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 min).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Additional Codes Status Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Electric panel room Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:"Milk Cooler" code or the International Building Code shall be installed, Comments:Appliances including motors or heat producing elements used and maintained in accordance with NFPA 70 and shall plug directly to a permanent outlet,currently cooler plugged to Sections 603.2 through 603.10. multi-plug adapter. OF E GENERATED ON 7/I6/26,8:09 AM Electrical Safety Status Code Description Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location: Kitchen -Above walk-in cooler prohibited. Approved covers shall be provided for all switch Comments: Provide missing cover to electric junction box. and electrical outlet boxes. Fail 603.4 -Working space and clearancesclearance. A working space of not Working space around electrical Location: Electric panel room equipment shall be provided in accordance with Section Comments: Remove storage within 36 inches of panel and maintain 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or clear unobstructed path of access to panel at all times. less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Fail 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked Location: Electric panel room with a plainly visible and legible sign stating "ELECTRICAL Comments: Provide approved "Electric Room" signage on door, ROOM" or similar approved wording. The disconnecting laminated paper will not be accepted. means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.3 - Installation. 0 Relocatable power tap cords shall not extend through walls, Location: Electric panel room ceilings, floors, under doors or floor coverings, or be subject Comments: Power strip currently hanging next to electric panel shall to environmental or physical damage. be properly mounted to wall or supported to avoid hanging by wires. Fail 603.6 - Extension cords. 0 Extension cords and flexible cordsshall not be a substitute Location: Menu TV's for permanent wiring and shall be listed and labeled in Comments: TV cords shall not pass through wall. If adding new accordance with UL 817. Extension cords and flexible outlets, licensed electrical contractor shall obtain permit and cordsshall not be affixed to structures, extended through inspection. walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 7/16/26, 8:09 AM 3 OF 5 Commercial Cooking Hood Suppression System Ssi_ss CCde Description Fail 606,3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Clean hood filters. Sections 606.3.3.1 through 606.3.3.3. Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression appurtenances shall be inspected at intervals specified in Comments:Provide suppression system inspection report with any Table 606.3.3.1 or as approved by the fire code official. deficiencies corrected.Contractor must upload report to Compliance Inspections shall be completed by qualified individuals. Engine.Last tagged for service by Hawkeye Fire&Safety in January 2026. 4 OF 5 GENERATED ON 7/16/26, 8:09 AM Elo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA N/A 5 OF 5 GENERATED ON 7/16/26, 8:09 AM