COMMERCIAL FIRE INSPECTION- 1730 W. RIDGEWAY AVE FOR BILLING INQUIRY: (319)291-4323
#600-7/14/26
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23835 07/16/2026 08/20/2026 2027-00000026 $80.00
Less Prepayment $0.00
Total Due —> $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
two Inspection Report 425 E.3rd Street
P Icon Donuts-1730 W Ridgeway AVE,BLDG 1730 W Ridgeway Ave-STE 600,
Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type i� n Inspection Number
07/14/2026 Annual Inspection(1Yr) ' f 8316
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 50 0 12 ® 13
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
08/1712026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-07115/2026 @ 08:03
•$80 annual inspection fee
BRAD BALDWIN-07/15/2026 @ 08:03
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-07115/2026 @ 08:03
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Ryan Drewes-2026 Date: BRAD BALDWIN 07/16/2026
CHECKLISTS
Emergency Equipment
Status Code Description
Fail 1203.2.15-Means of egress illumination.
'x Emergency power shall be provided for means of egress Location:Kitchen
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate
during test.Also,one of the egress lights currently damaged
(hanging by wires)shall be corrected.
GENERATED ON 7/16/26, 8:09 AN 1 OF 5
General Housekeeping
Description
Fail 304.3.1-Spontaneous ignition.
Materials susceptible to spontaneous ignition,such as oily Location:Kitchen
rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self closing lid for soiled
of such containers shall be removed and disposed of daily. rag disposal.Rags containing fats,oils or grease shall be disposed in
container and removed from the building daily.
Fire Service Features
Status Code Description
Fail 505.1-Address identification.
New and existing buildings shall be provided with approved Location:Front of building
address identification.The address identification shall be Comments:"Suite 500"numbers shall be installed to comply with
legible and placed in a position that is visible from the street code requirements.Numbers shall be in contrast with the building
or road fronting the property.Address identification and easily visible from the road.
characters shall contrast with their background.Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke
width of 112 inch(12.7 min).Where required by the fire code
official,address identification shall be provided in additional
approved locations to facilitate emergency response.Where
access is by means of a private road and the building cannot
be viewed from the public way,a monument,pole or other
sign or means shall be used to identify the structure.Address
identification shall be maintained.
Additional Codes
Status Code Description
Fail 5303.5.3-Securing compressed gas containers,cylinders
and tanks. Location:Electric panel room
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
Fail 603.1-General.
Electrical equipment,wiring and systems required by this Location:"Milk Cooler"
code or the International Building Code shall be installed, Comments:Appliances including motors or heat producing elements
used and maintained in accordance with NFPA 70 and shall plug directly to a permanent outlet,currently cooler plugged to
Sections 603.2 through 603.10. multi-plug adapter.
OF E
GENERATED ON 7/I6/26,8:09 AM
Electrical Safety
Status Code Description
Fail 603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location: Kitchen -Above walk-in cooler
prohibited. Approved covers shall be provided for all switch Comments: Provide missing cover to electric junction box.
and electrical outlet boxes.
Fail 603.4 -Working space and clearancesclearance.
A working space of not Working space around electrical Location: Electric panel room
equipment shall be provided in accordance with Section Comments: Remove storage within 36 inches of panel and maintain
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or clear unobstructed path of access to panel at all times.
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
Fail 603.4.1 - Labeling.
Doors into electrical control panel rooms shall be marked Location: Electric panel room
with a plainly visible and legible sign stating "ELECTRICAL Comments: Provide approved "Electric Room" signage on door,
ROOM" or similar approved wording. The disconnecting laminated paper will not be accepted.
means for each service, feeder or branch circuit originating
on a switchboard or panelboard shall be legibly and durably
marked to indicate its purpose unless such purpose is clearly
evident. Where buildings or structures are supplied by more
than one power source, markings shall be provided at each
service equipment location and at all interconnected electric
power production sources identifying all electric power
sources at the premises in accordance with NFPA 70.
Fail 603.5.3 - Installation.
0 Relocatable power tap cords shall not extend through walls, Location: Electric panel room
ceilings, floors, under doors or floor coverings, or be subject Comments: Power strip currently hanging next to electric panel shall
to environmental or physical damage. be properly mounted to wall or supported to avoid hanging by wires.
Fail 603.6 - Extension cords.
0 Extension cords and flexible cordsshall not be a substitute Location: Menu TV's
for permanent wiring and shall be listed and labeled in Comments: TV cords shall not pass through wall. If adding new
accordance with UL 817. Extension cords and flexible outlets, licensed electrical contractor shall obtain permit and
cordsshall not be affixed to structures, extended through inspection.
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
GENERATED ON 7/16/26, 8:09 AM 3 OF 5
Commercial Cooking Hood Suppression System
Ssi_ss CCde Description
Fail 606,3.3-Cleaning.
Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust
appurtenances shall be cleaned at intervals as required by Comments:Clean hood filters.
Sections 606.3.3.1 through 606.3.3.3.
Fail 606.3.3.1-Inspection.
Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression
appurtenances shall be inspected at intervals specified in Comments:Provide suppression system inspection report with any
Table 606.3.3.1 or as approved by the fire code official. deficiencies corrected.Contractor must upload report to Compliance
Inspections shall be completed by qualified individuals. Engine.Last tagged for service by Hawkeye Fire&Safety in January
2026.