Loading...
HomeMy WebLinkAbout201 RATH ST W A INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-00000052 $80.00 • *1- tf•fi}f/Y tf lY t • `IVti \ Customer#: 24139 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable VINTON'S PUB AND EATERY 715 Mulberry St 201 RATH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-201 RATH ST- 7-12-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24139 07/18/2023 08/20/2023 2024-00000052 $80.00 Less Prepayment $0.00 Total Due -f $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 4p1ER`oO INSPECTION REPORT r r VINTON'S PUB AND EATERY,201 RATH ST,BLDG 201 RATH ST,WATERLOO IA 50703 DETAILS Inspection Date:07/12/2023 I Inspection Type:Annual Inspection(1Yr) i Inspection Number: 10644 Shift: N/A I Station: N/A j Unit: N/A • Lead Inspector:JEREMIAH VANDYKE Other Inspectors:JEFF SIEBEL ! Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1004.9-Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load of load. the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space,for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Inspector:JEREMIAH VANDYKE-Comments:Inspector Siebel is re calculating and will have new sign available for posting. Location: Not Provided FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3.2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3. Exit access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4, Item 8.4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13,Item 3.Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain overcurrent devices,switching devices or control devices with exit or exit access doors,shall be equipped with panic hardware or fire exit hardware.The doors shall swing in the direction of egress travel. Inspector:JEREMIAH VANDYKE-Comments:Front corner door exit sign is to be removed or covered OR install panic hardware.AND back door(with thumb key lock) must have durable sign stating"Door must be unlocked during business hours". Please call if you have any questions. Location: Not Provided FAIL 2311.2.3.2-Disposal of oily Self-closing metal cans shall be used for oily waste. waste. Inspector:JEREMIAH VANDYKE-Comments:UL listed oily waste can(Red can)needed in kitchen. Location: Not Provided Printed on 07/13/2023 @ 08:13 Page 1 of 4 STATUS CODE DESCRIPTION FABL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of -/ ., compressed gas containers,cylinders and tanks at container filling or servicing \--1— - facilities or in sellers'warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks, if dislodged,do not obstruct_ the required means of egress.4.Securing of compressed gas containers,cylinders i p-- and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process �ti ' of examination,filling,transport or servicing. Inspector:JEREMIAH VANDYKE-Comments: Must remove or secure red cylinder. Location:Old cooler. FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEREMIAH VANDYKE-Comments: Need appropriate outlet for appliance plug in. ' ��; �- Location: Back kitchen 4 a„ z Printed on 07/13/2023 @ 0813 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a usePower supply. permanently installed receptacle. Exceptions: 1.Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2. A `' Current taps and relocatable power taps shall not be required to connect directly to )'.> ,, a permanently installed receptacle outlet where used for 90 days or less for the . purpose of testing the performance of such devices. ---111t1KOPV. Inspector:JEREMIAH VANDYKE-Comments:Must remove power strip/tap and install t / ' ' more outlets for coolers and freezer behind bar. 1 Location: Behind bar. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental .z damage or physical impact. Extension cords shall be used only with portable Y appliances. Extension cords marked for indoor use shall not be used outdoors. a Inspector:JEREMIAH VANDYKE-Comments:Can not use extension cords as permanent wiring. Install outlet. ) Location:Cooler behind bar. GENERAL NOTES JEREMIAH VANDYKE-07/12/2023 @ 14:46 Hood cleaned JEREMIAH VANDYKE-07/12/2023 @ 16:08 Back kitchen has gas capped and out of service. JEREMIAH VANDYKE-07/12/2023 @ 16:08 Back kitchen has gas capped and out of service. JEREMIAH VANDYKE-07/12/2023 @ 16:08 Fire extinguishers compliant/serviced by Pro shield in Mat 2023. JEREMIAH VANDYKE-07/12/2023 @ 16:11 Hood suppression inspected on 5/31/2023 by Pro Shield and uploaded to compliance engine. Printed on 07/13/2023 @ 08:13 Page 3 of 4 GENERAL NOTES JEREMIAH VANDYKE-07/12/2023 @ 16:17 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-07/12/2023 @ 16:17 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-07/12/2023 @ 16:18 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-07/12/2023 @ 16:18 Inspection Fee=$80.00 REINSPECTION DATE 08/11/2023 CONTACT SIGNATURE Damiane Carter Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:07/12/2023 @ 16:15b/C7LJ QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 07/13/2023 @ 08:13 Page 4 of 4