Loading...
HomeMy WebLinkAbout2830 UNIVERSITY AVE W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE " f 07/18/2023 08/20/2023 2024-00000051 $200.00 .› �.,.�_ 0 Customer#: 24138 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable THIRTEEN ASSOCIATES LLC 715 Mulberry St 181 SOUTH FRANKLIN APT 607 WATERLOO, IA 50703 NORTH WOODMERE,NY 11581 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2830 UNIVERSITY AVE- 6-12-23 FOR BILLING INQUIRY: (319)291-4323 L`Description I Total Price REINSPECTION 3 $200.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24138 07/18/2023 08/20/2023 2024-00000051 $200.00 Less Prepayment $0.00 Total Due —> $200.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. } C \‘`I'1\ w a .)\ A TERL OO F/RE RESCUE �� , INSPECTION REPORT */ -\ *Na: BLD6 2330 UNIVERSITYAVE,2830 UNIVERSITYAVE,WATERLOO/A 50701 c _ \ , DETAILS sei°11'd Inspection Date:06/12/2023 ! Inspection Type:Annual Inspection(1Yr) Inspection Number: 10177 Shift: N/A j Station: N/A j Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors:BROCK WELIVER ! Fee:$200.00 STATUS CODE DESCRIPTION FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Inspector:JEREMIAH VANDYKE-Comments:CONTACT FIRE SPRINKLER COMPANY TO CORRECT.1.System has past Deficiency Found:Answer:OS&Y control valve leaks and unable to adjust packing. Needs replaced. Needs to be inspected by licensed sprinkler contractor and inspection report uploaded into Compliance Engine by servicing contractor. Location: Not Provided Printed on 06/12/2023 @ 14:47 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEREMIAH VANDYKE-Comments: Located in Furnace/mechanical room. Fire resistance sheet rock is to be REPLACED on ceiling. Location: Not Provided GENERAL NOTES Printed on 06/12/2023 @ 14:47 Page 2 of 3 JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- • JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re inspection fee:$200.00 JEREMIAH VANDYKE-06/12/2023 @ 14:46 Stopped by and attempted to make contact with Steve Jordan via phone call.Number disconnected. REINSPECTION DATE 07/12/2023 CONTACT SIGNATURE Steven Jordan Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE (671.1, Signed on:06/12/2023 @ 14:45 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 06/12/2023 @ 14:47 Page 3 of 3