COMMERCIAL INSPECTION - 2830 UNIVERSITY AVE- 6-12-23 FOR BILLING INQUIRY: (319)291-4323
L`Description I Total Price
REINSPECTION 3 $200.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24138 07/18/2023 08/20/2023 2024-00000051 $200.00
Less Prepayment $0.00
Total Due —> $200.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
}
C \‘`I'1\
w a .)\
A TERL OO F/RE RESCUE �� ,
INSPECTION REPORT */ -\ *Na:
BLD6 2330 UNIVERSITYAVE,2830 UNIVERSITYAVE,WATERLOO/A 50701 c _ \ ,
DETAILS
sei°11'd
Inspection Date:06/12/2023 ! Inspection Type:Annual Inspection(1Yr) Inspection Number: 10177 Shift: N/A j Station: N/A j
Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors:BROCK WELIVER ! Fee:$200.00
STATUS CODE DESCRIPTION
FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Inspector:JEREMIAH VANDYKE-Comments:CONTACT FIRE SPRINKLER COMPANY TO
CORRECT.1.System has past Deficiency Found:Answer:OS&Y control valve leaks and
unable to adjust packing. Needs replaced. Needs to be inspected by licensed
sprinkler contractor and inspection report uploaded into Compliance Engine by
servicing contractor.
Location: Not Provided
Printed on 06/12/2023 @ 14:47
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:JEREMIAH VANDYKE-Comments: Located in Furnace/mechanical room.
Fire resistance sheet rock is to be REPLACED on ceiling.
Location: Not Provided
GENERAL NOTES
Printed on 06/12/2023 @ 14:47
Page 2 of 3
JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
•
JEREMIAH VANDYKE-05/04/2023 @ 14:17 Re inspection fee:$200.00
JEREMIAH VANDYKE-06/12/2023 @ 14:46 Stopped by and attempted to make contact with Steve Jordan via phone call.Number
disconnected.
REINSPECTION DATE
07/12/2023
CONTACT SIGNATURE
Steven Jordan Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
(671.1,
Signed on:06/12/2023 @ 14:45