COMMERCIAL INSPECTION - 1961 INDEPENDENCE AVE- 7-11-23 FOR BILLING INQUIRY: (319)291-4323
L Description ) Total Price
INSPECTION 1 $40.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24134 07/18/2023 08/20/2023 2024-00000037 $50.00
Less Prepayment $0.00
Total Due -* $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
NEW DEAL MOTORS,1961 INDEPENDENCEAVE,BLDG 1961 INDEPENDENCEAVE,WATERLOO
IA 50703
DETAILS
Inspection Date:07/11/2023 I Inspection Type:Annual Inspection(1Yr) ! Inspection Number:416 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A Fee:$50.00
STATUS CODE DESCRIPTION
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEREMIAH VANDYKE-Comments:Open junction box with exposed wiring
needs to have approved cover.Will send picture after complete.
Location:Ceiling light connection.
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.Joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEREMIAH VANDYKE-Comments:Open holes in ceiling X2 need to be
repaired.Will send picture after repaired.
Location:Ceiling.
Printed on 07/11/2023 @ 15:10
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned, properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEREMIAH VANDYKE-Comments:Looking for receipt for newer fire
extinguishers that are hanging on wall that were purchased privately.If unable to find
will go to Fire extinguisher contractor to purchase new extinguishers and will send
picture of receipt of invoice or tag on extinguishers.
Location:2 extinguishers is building.
GENERAL NOTES
JEREMIAH VANDYKE-07/11/2023 @ 15:09 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-07/11/2023 @ 15:09 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-07/11/2023 @ 15:09 Inspection Fee=$50.00
REINSPECTION DATE
08/10/2023
CONTACT SIGNATURE
Ernie Tahirovic Reason for not collecting a signature:NA
Printed on 07/11/2023 @ 15:10
Page 2 of 3
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
y / n/7u
Signed on:07/11/2023 @ 15:01
QUESTIONS ABOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 07/11/2023 @ 15:10
Page 3of3
GENERAL NOTES
JEFF SIEBEL-07/18/2023 @ 09:20
JEFF SIEBEL-07/18/2023 @ 09:23
REINSPECTION DATE
08/21/2023
CONTACT SIGNATURE
Becky Mckeithan corporate 2023
Signed on:07/18/2023 @ 09:15 KL (! C
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:07/18/2023 @ 09:15