Loading...
HomeMy WebLinkAbout1961 INDEPENDENCE AVE WA r INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-00000037 $50.00 0 i'!l/„„,„„-. • .,�Y at",tt tt tY i IV 0 Wbl-- Customer#: 24134 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable NEW DEAL MOTORS 715 Mulberry St 1961 INDEPENDENCE AVE WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1961 INDEPENDENCE AVE- 7-11-23 FOR BILLING INQUIRY: (319)291-4323 L Description ) Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24134 07/18/2023 08/20/2023 2024-00000037 $50.00 Less Prepayment $0.00 Total Due -* $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT NEW DEAL MOTORS,1961 INDEPENDENCEAVE,BLDG 1961 INDEPENDENCEAVE,WATERLOO IA 50703 DETAILS Inspection Date:07/11/2023 I Inspection Type:Annual Inspection(1Yr) ! Inspection Number:416 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A Fee:$50.00 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEREMIAH VANDYKE-Comments:Open junction box with exposed wiring needs to have approved cover.Will send picture after complete. Location:Ceiling light connection. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Open holes in ceiling X2 need to be repaired.Will send picture after repaired. Location:Ceiling. Printed on 07/11/2023 @ 15:10 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:Looking for receipt for newer fire extinguishers that are hanging on wall that were purchased privately.If unable to find will go to Fire extinguisher contractor to purchase new extinguishers and will send picture of receipt of invoice or tag on extinguishers. Location:2 extinguishers is building. GENERAL NOTES JEREMIAH VANDYKE-07/11/2023 @ 15:09 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-07/11/2023 @ 15:09 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-07/11/2023 @ 15:09 Inspection Fee=$50.00 REINSPECTION DATE 08/10/2023 CONTACT SIGNATURE Ernie Tahirovic Reason for not collecting a signature:NA Printed on 07/11/2023 @ 15:10 Page 2 of 3 INSPECTOR SIGNATURE JEREMIAH VANDYKE y / n/7u Signed on:07/11/2023 @ 15:01 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 07/11/2023 @ 15:10 Page 3of3 GENERAL NOTES JEFF SIEBEL-07/18/2023 @ 09:20 JEFF SIEBEL-07/18/2023 @ 09:23 REINSPECTION DATE 08/21/2023 CONTACT SIGNATURE Becky Mckeithan corporate 2023 Signed on:07/18/2023 @ 09:15 KL (! C INSPECTOR SIGNATURE JEFF SIEBEL Signed on:07/18/2023 @ 09:15 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 07/18/2023 @ 09:26 Page 2 of 2