Loading...
HomeMy WebLinkAbout1210 FLAMMANG DR } W A r INVOICE DATE DUE DATE INVOICE## TOTAL DUE ' 0 07/18/2023 08/20/2023 2024-00000034 v - � $100.00 irr >s��rr��r. ivilN Customer#: 24125 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STUFF ECT 715 Mulberry St 1210 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1210 FLAMMANG DR- 5-31-23 FOR BILLING INQUIRY: (319)291-4323 I L Description I Total Price j INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER# BILLING`DATE DUE DATE 24125 I 07/18/2023 INVOICE# CHARGES I 08/20/2023 _ I 2024 0000003 4 $100.00 Less Prepayment $0.00 Total Due --> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. u3 W A TERL 00 FIRE RESCUE INSPECTION REPORT STUFF ECT, 1210 FLAMMANG DR,BLDG 1210 FLAMMANG DR,WATERLOO IA S0702 , \ DETAILS Inspection Date:05/31/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number: 1728 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:All emergency egress lights in building need to be addressed by Electrician with work order complete or invoice. Location:Entire building FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:Missing Exit sign that must be replaced above door. Location:Loading dock area FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments:All emergency EGRESS AND EXIT lights in building need to be addressed by Electrician with work order complete or invoice. Location:Entire building Printed on 0610 1/2 023 @ 15:58 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments:Panel states Radio Trouble,needs addressed by fire alarm contractor. • Location: IT room in back s 1. :. .�A . 3Z 411110 FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEREMIAH VANDYKE-Comments:Keys needed for access for ALL locked doors to be placed in Knox box. Location: Not Provided FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments:Signage stating"FDC"made of durable material needed above FDC connection. Location:Outside above fire department connection. Printed on 06/01/2023 @ 15:58 Page 2 of 6 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be - not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). ER Inspector:Ins „�, p J EMIAH VANDYKE-Comments:Clearance of 36 inches in front of electrical panels. Location:IT room FAIL 603.4.1 -Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating"ELECTRICAL ROOM"or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Inspector:JEREMIAH VANDYKE-Comments:Signage needed on door stating"Main Electrical Panel". Location: IT room/main electrical room FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a usePower supply. permanently installed receptacle.Exceptions: 1.Where approved for use in a Group A occupancy or in a meeting room in a Group S occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Inspector:JEREMIAH VANDYKE-Comments:Power tap daisy chained under desk. Location:Pricing area. FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Printed on 06/01/2023 @ 15:58 Page 3of6 STATUS CODE DESCRIPTION Inspector:JEREMIAH VANDYKE-Comments:Under rubber mat. Viti* Location: Pricing area. 4.7 =s FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEREMIAH VANDYKE-Comments:Red extension cord cannot be used as • permanent wiring and under rubber mat.Yellow extension cord needs to be removed from ceiling. Location: Pricing area and Main electrical room in back. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Missing ceiling tile. Location:Outside women's restroom. GENERAL NOTES JEREMIAH VANDYKE-05/31/2023 @ 16:11 Fire extinguishers serviced/compliant by Hawkeye Fire anfpd safety in May 2023. Pnntea on 06/01/2023 @ 15:58 Page 4 of 6 GENERAL NOTES JEREMIAH VANDYKE-06/01/2023 @ 15:51 04/13/2023 S-(Annual)Fire Alarm HAWKEYE COMMUNICATION Reviewed Compliant JEREMIAH VANDYKE-06/01/2023 @ 15:52 04/10/2023 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS,INC. Reviewed Compliant JEREMIAH VANDYKE-06/01/2023 @ 15:57 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-06/01/2023 @ 15:57 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-06/01/2023 @ 15:57 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-06/01/2023 @ 15:58 Inspection Fee=$100.00 REINSPECT/ON DATE 07/01/2023 CONTACT SIGNATURE Chris Jung Reason for not collecting a signature:NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:06/01/2023 @ 15:52 Li/ L6 Printed on 06/01/2023 @ 15:58 Page 5 of 6 QUESTIONS AMOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 06/01/2023 @ 15:58 Page 6 of 6