Loading...
HomeMy WebLinkAbout1150 FLAMMANG DR O W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-00000033 $100.00 Yi■'i • .0 y.,...t./. •y 0 ti 0ts •, it/11N Customer#: 24124 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STUFF ETC 715 Mulberry St 1150 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1150 FLAMMANG DR- 5-31-23 FOR BILLING INQUIRY: (319)291-4323 L Description v I Total�Pricej INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24124 07/18/2023 08/20/2023 2024-00000033 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. v- WATERLOO FIRE RESCUE " otstk,INSPECTION REPORT STUFF ETC.,1150 FLAMMA/VG DR,BLDG 1150 FLAAMAN6DR-STE200,WATERLOO IA 50702 DETAILS Inspection Date:05/31/2023 Inspection Type:Annual Inspection(1 Yr) Inspection Number: 10366 Shift: N/A Station: N/A Unit: N/A i Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A i Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEREMIAH VANDYKE-comments:Marked exit double doors is hard to open and needs to be repaired. Location: Back storage area double doors FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:Egress lights tested and failed.Must be addressed by electrician with work order or invoice. Location: Entire building FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:Exit lights tested and failed.Must be addressed by electrician with work order or invoice. Location: Entire Building Printed on 06/01/2023 @ 16:06 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments:All EXIT and EGRESS lights must be addressed by electrician with work order or invoice. Location: Entire Building. GENERAL NOTES JEREMIAH VANDYKE-06/01/2023 @ 16:03 Fire extinguishers serviced/compliant by Hawkeye Fire and Safety in May 2023. JEREMIAH VANDYKE-06/01/2023 @ 16:04 04/13/2023 S-(Annual)Fire Alarm HAWKEYE COMMUNICATION Reviewed Compliant JEREMIAH VANDYKE-06/01/2023 @ 16:04 04/10/2023 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE-06/01/2023 @ 16:04 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-06/01/2023 @ 16:04 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-06/01/2023 @ 16:04 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- REINSPECTION DATE 07/01/2023 CONTACT SIGNATURE Chris Jung Reason for not collecting a signature: NA Printed on 06/01/2023 @ 16:06 Page 2 of 3 INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:06/01/2023 @ 16:05 J QUESTIONS AIOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 06/01/2023 @ 16:06 Page 3 of 3