Loading...
HomeMy WebLinkAbout5 N ELK RUN RD WA T INVOICE DATE DUE DATE tfi INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-00000032 $50.00 ik • r• rrrt■ar 0 O. 46. Customer#: 24132 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ANNA'S KITCHEN 715 Mulberry St 5 N ELK RUN RD WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 5 N ELK RUN RD - 6-28-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE I INVOICE# 24132 07/18/2023 08/20/2023 2024-00000032 CHARGES $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. , `NeJ3 WATERLOO FIRE RESCUE LI ) a INSPECTION REPORT Iry ANNA'S KITCHEN,Sip N ELK RUN RD,BLDG 5 N ELK RUN RD,WATERLOO IA 50703 -6 tVi DETAILS Inspection Date:06/28/2023 ; Inspection Type:Annual Inspection(1Yr) j Inspection Number:335 j Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE ; Other Inspectors:BROCK WELIVER j Fee:$50.00 STATUS CODE DESCRIPTION a a->: '_ 1004.9-Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load of load. the room or space posted in a conspicuous place,near the main exit or exit access doorway from the room or space,for the intended configurations.Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Inspector:JEREMIAH VANDYKE-Comments:Fire Inspector will bring occupancy load sign out. Location: Not Provided FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEREMIAH VANDYKE-Comments:Contact City of Waterloo Building Department for proper installation of the outside shade covers for customers.Will require inspection by County Building inspector. ,,,, , iv; Fi E__:- ,i I r Location:Outside r91- FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Printed on 06/28/2023 @ t 5:15 Page 1 of 5 STATUS CODE DESCRIPTION Inspector:JEREMIAH VANDYKE-Comments:UL listed container is needed in kitchen for greasy rag disposal. Location: Kitchen @ASO l w - FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:JEREMIAH VANDYKE-Comments:Panel covered was removed for construction and must be installed. Location: Main electrical panel FAIL 603.4.1 -Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating"ELECTRICAL ROOM"or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Inspector:JEREMIAH VANDYKE-Comments:Signage needed for door stating"Main Electrical Panel" Location: Main electrical panel/furnace room. Printed on 06/28/2023 @ 15:15 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 606.3.3.1 -Inspection. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Inspector:JEREMIAH VANDYKE-Comments:Contact AKA cleaning who did the hood cleaning to have them upload cleaning report to Compliance Engine. Location: Kitchen hood FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system. Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEREMIAH VANDYKE-Comments:Contact Pro shield to have hood suppression system inspected and have contractor upload report to Compliance Engine after work completed. Location: Kitchen FAIL 906.2-General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:Fire extinguisher needed in dining area and properly mounted in conspicuous location. Location: Dining area Printed on 06/28/2023 @ 15:15 Page 3of5 STATUS CODE DESCRIPTION FAIL 906.4.2-Class K portable fire Where hazard areas include deep fat fryers,listed Class K portable fire extinguishers extinguishers for deep fat shall be provided as follows: 1.For up to four fryers having a maximum cooking fryers. medium capacity of 80 pounds(36.3 kg)each:one Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity.2.For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds(36.3 kg)each:one additional Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity shall be provided.3.For individual fryers exceeding 6 square feet(0.55 m2)in surface area:Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturer's recommendations. Inspector:JEREMIAH VANDYKE-Comments:Class K extinguisher to be serviced and hung in conspicuous spot. Location: Kitchen area. GENERAL NOTES JEREMIAH VANDYKE-06/28/2023 @ 14:58 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-06/28/2023 @ 14:58 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-06/28/2023 @ 14:58 Inspection Fee=$50.00 REINSPECTION DATE 07/28/2023 CONTACT SIGNATURE Snjezana Jovanovic Reason for not collecting a signature:NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:06/28/2023 @ 15:14 Printed on 06/28/2023 @ 15:15 Page 4 of 5 QUESTIONS AIOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 06/28/2023 @ 15:15 Page 5 of 5