Loading...
HomeMy WebLinkAbout306 BYRON AVE Q* W4 74' INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-00000030 $80.00 �`f,����rrr�rrrrrf>rr, 4 Y■t.�. .Y`1 YY YY . 11�`w,��,■� I 0 46. AIf Ms Customer#: 23002 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GUDDI MART 715 Mulberry St 306 BYRON WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-306 BYRON AVE- 7-17-23 FOR BILLING INQUIRY: (319)291-4323 l Description Total Price.j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23002 07/18/2023 08/20/2023 2024-00000030 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. - - 2 WATERLOO FIRE RESCUEc. 3ypSERlp. ��� INSPECTION REPORT t 6UDDI MART,306 BYRONAVE,BLDG 306 BYRONAVE,WATERLOO/A 50702 DETAILS Inspection Date:07/17/2023 1 Inspection Type:Annual Inspection(1Yr) I Inspection Number:8298 I Shift: N/A I Station: N/A Unit: N/A 1 Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair exit/egress light above door. Location:Side exit to the North FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed �p for the movement of compressed gas containers,cylinders or tanks.3. Nesting of #� - � '� compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed A---/ provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct drill.../ _. .., , the required means of egress.4.Securing of compressed gas containers,cylinders ,I ` — and tanks to or within a rack,framework,cabinet or similar assembly designed for � , , such use. Exception:Compressed gas containers,cylinders and tanks in the process , of examination,filling,transport or servicing. ' Inspector:JEFF SIEBEL-Comments:Remove propane cylinders from the building. 1 a Location: Back Room r 4 k Printed on 07/18/2023 @ 08:22 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:Coolers must plug directly into permanent wall outlet.remove power strip. Location:front of store by Cutwater,Core, Red Bull coolers FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers Location: Not Provided GENERAL NOTES JEFF SIEBEL-07/18/2023 @ 08:20 annual inspection$80 REINSPECTION DATE 08/07/2023 CONTACT SIGNATURE Ace Mohsin Ansar Signed on:07/18/2023 @ 08:21 Printed on 07/18/2023 @ 08:22 Page 2of3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:07/18/2023 @ 08:21 11/ QUESTIONS AMOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 07/18/2023 @ 08:22 Page 3 of 3