Loading...
HomeMy WebLinkAbout1459 ANSBOROUGH AVE (2) Q� T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/18/2023 08/20/2023 2024-0000002' $80.00 O r rissi • r ..tin. s r- r-s sr 3S 7 d 11N Customer#: 24128 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BEST DEALS 715 Mulberry St 1459 ANSBOROUGH AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1459 ANSBOROUGH AVE -4-25-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24128 07/18/2023 08/20/2023 2024-00000027 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 7%6 WATERLOO FIRE RESCUE \, INSPECTION REPORT / \ '_ BEST DEALS,1459 ANSBOROUGH AVE,BLDG 1459 ANSBOROUGH AVE,WATERLOO/A S0701 DETAILS Inspection Date:04/25/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:7805 ; Shift: N/A ; Station: N/A Unit: N/A j Lead Inspector:JEFF SIEBEL ± Other Inspectors: N/A j Fee:$80.00 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:replace missing breaker in the electrical panel or install a listed blank. Location:front of store FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments: Remove obstructions to electrical pane. Maintain a minimum of 36"clearance at all times. Location: Front and back room of Store Printed on 05/24/2023 @ 10:08 Page 1 of 3 STATUS CODE DESCRIPTION i A L 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing attic door in ceiling. Location:liquor room FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. Location: Not Provided REINSPECTION DATE 05/17/2023 Printed on 05/24/2023 @ 10:08 Page 2 of 3 CONTACT SIGNATURE Saj Mukhtar Signed on:04/27/2023 @ 13:34 2 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/27/2023 @ 13:34 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/24/2023 @ 10:08 Page 3 of 3