COMMERCIAL INSPECTION- 1307 W 5TH ST- 6-2-23 FOR BILLING INQUIRY: (319)291-4323
[Description
` Total Price]
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
6637 07/07/2023 08/10/2023 2024-00000024 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT ""'
4:ODi
LIGHTHOUSE LOUNGE, 1307 W STH ST,BLD6 1307 W STH ST,WATERLOO IA S0702
DETAILS
Inspection Date:06/02/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:8314 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEFF SIEBEL-Comments: Install outlet cover on GFCI outlet
Location:above sink in back kitchen area
FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under
doors or floor coverings,or be subject to environmental or physical damage.
Inspector:JEFF SIEBEL-Comments:None
Location:behind bar by fire extinguisher
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned, properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers
Location: Not Provided
GENERAL NOTES
JEFF SIEBEL-06/02/2023 @ 13:26 annual inspection$80
Printed on 06/02/2023 @ 13:50
Page 1 of 2
REINSPECTION DATE
06/23/2023
CONTACT SIGNATURE
Stainbrook
Signed on:06/02/2023 @ 13:27 e c'. b y
S� rn,h1-f-d •V/\
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:06/02/2023 @ 13:27