COMMERCIAL INSPECTION-3906 W AIRLINE HWY-6-27-23 FOR BILLING INQUIRY: (319)291-4323
L Description
Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER#_; . BILLING DATE DUE DATE INVOICE# CHARGES
15536 07/07/2023 08/10/2023 2024-00000003 $80.00
Less Prepayment $0.00
Total Due— $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
a V
WATERLOO FIRE RESCUE ) (31"
INSPECTION REPORT IC1)
HOFFMAN&HOFFMAN TRENCHING INC,3822 W AIRLINE HWY,BLDG 3822 W AIRLINE HWY.
WATERLOO/A 50703
DETAILS
Inspection Date:06/29/2023 I Inspection Type:Annual Inspection(1Yr) ) Inspection Number:209 I Shift: N/A ( Station: N/A
Unit: N/A I Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A ( Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEREMIAH VANDYKE-Comments:All Emergency lights and Exit lights need
to be repaired or replaced.
Location:Office and shop.
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEREMIAH VANDYKE-Comments:All Emergency lights and Exit lights need
to be repaired or replaced.
Location:Office and shop.
FAIL 4006.1 -Hazard identification Unless otherwise exempted by the fire code official,visible hazard identification
signs. signs,as specified in NFPA 704 for the specific material contained,shall be placed on
stationary containers and above-ground tanks;at entrances to locations where
hazardous materials are stored,dispensed,used or handled in quantities requiring a
permit;and at specific entrances and locations designated by the fire code official.
Inspector:JEREMIAH VANDYKE-Comments:Proper hazard identification signs
needed on out side of building in conspicuous location.
Location:Shop/Office
Printed on 06/29/2023 @ 11:35
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 506.1 -Where required. Where access to or within a structure or an area is restricted because of secured
openings or where immediate access is necessary for life-saving or fire-fighting
purposes,the fire code official is authorized to require a key box to be installed in an
approved location.The key box shall be of an approved type listed in accordance with
UL 1037,and shall contain keys to gain necessary access as required by the fire code
official.
Inspector:JEREMIAH VANDYKE-Comments:Building was found to have Fire Alarm.
Owner is contacting contractor to have inspected.A Knox Box will be required after
fire alarm is inspected per code and city ordinance.Will assist in ordering process of
KnoxBox.
Location: Not Provided
FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor
testing,and maintenance
Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm found in building.Owner
contacting Licensed Fire Alarm contractor to have inspected. Report is to be
uploaded to Compliance Engine by servicing contractor.
Location:Not Provided
GENERAL NOTES
JEREMIAH VANDYKE-06/29/2023 @ 11:34 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in
the event of an emergency at that address.Phone#319-291-2515.
JEREMIAH VANDYKE-06/29/2023 @ 11:34 Re-inspection dates are automatically generated 30 days out from the initial
inspection.Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-06/29/2023 @ 11:34 Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-06/29/2023 @ 11:35 Inspection Fee=$80.00
JEREMIAH VANDYKE-06/29/2023 @ 11:15 Fire extinguisher serviced/compliant by Pro Shield in March 2023.
JEREMIAH VANDYKE-06/29/2023 @ 11:19 Discussed Lithium batteries.
Printed on 06/29/2023 @ 11:35
Page 2 of 3
REINSPECTION DATE
07/29/2023
CONTACT SIGNATURE
Nick Hoffman Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE Vij
Signed on:06/29/2023 @ 11:35
QUESTIONS ADOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 06/29/2023 @ 11:35
Page 3 of 3