Loading...
HomeMy WebLinkAbout3906 W AIRLINE HWY of W . INVOICE DATE DUE DATE INVOICE# TOTAL DUE dP0 07/07/2023 08/10/2023 2024-00000003 $80.00 U.,Miffop. f o • •III,. mu II III • ) 4-4 Customer#: 15536 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BLACK HAWK TOOLING INC 715 Mulberry St 2503 FALLS AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3906 W AIRLINE HWY-6-27-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER#_; . BILLING DATE DUE DATE INVOICE# CHARGES 15536 07/07/2023 08/10/2023 2024-00000003 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. a V WATERLOO FIRE RESCUE ) (31" INSPECTION REPORT IC1) HOFFMAN&HOFFMAN TRENCHING INC,3822 W AIRLINE HWY,BLDG 3822 W AIRLINE HWY. WATERLOO/A 50703 DETAILS Inspection Date:06/29/2023 I Inspection Type:Annual Inspection(1Yr) ) Inspection Number:209 I Shift: N/A ( Station: N/A Unit: N/A I Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A ( Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:All Emergency lights and Exit lights need to be repaired or replaced. Location:Office and shop. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:All Emergency lights and Exit lights need to be repaired or replaced. Location:Office and shop. FAIL 4006.1 -Hazard identification Unless otherwise exempted by the fire code official,visible hazard identification signs. signs,as specified in NFPA 704 for the specific material contained,shall be placed on stationary containers and above-ground tanks;at entrances to locations where hazardous materials are stored,dispensed,used or handled in quantities requiring a permit;and at specific entrances and locations designated by the fire code official. Inspector:JEREMIAH VANDYKE-Comments:Proper hazard identification signs needed on out side of building in conspicuous location. Location:Shop/Office Printed on 06/29/2023 @ 11:35 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 506.1 -Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector:JEREMIAH VANDYKE-Comments:Building was found to have Fire Alarm. Owner is contacting contractor to have inspected.A Knox Box will be required after fire alarm is inspected per code and city ordinance.Will assist in ordering process of KnoxBox. Location: Not Provided FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm found in building.Owner contacting Licensed Fire Alarm contractor to have inspected. Report is to be uploaded to Compliance Engine by servicing contractor. Location:Not Provided GENERAL NOTES JEREMIAH VANDYKE-06/29/2023 @ 11:34 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-06/29/2023 @ 11:34 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-06/29/2023 @ 11:34 Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-06/29/2023 @ 11:35 Inspection Fee=$80.00 JEREMIAH VANDYKE-06/29/2023 @ 11:15 Fire extinguisher serviced/compliant by Pro Shield in March 2023. JEREMIAH VANDYKE-06/29/2023 @ 11:19 Discussed Lithium batteries. Printed on 06/29/2023 @ 11:35 Page 2 of 3 REINSPECTION DATE 07/29/2023 CONTACT SIGNATURE Nick Hoffman Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Vij Signed on:06/29/2023 @ 11:35 QUESTIONS ADOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 06/29/2023 @ 11:35 Page 3 of 3