Loading...
HomeMy WebLinkAbout1106 LA PORTE RD O F 11114 A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE e 07/07/2023 08/10/2023 2024-00000015 $80.00 • •nnunuuI mil • • T— ♦ 0 6. Customer#: 4470 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DAD'S PUB 715 Mulberry St 1106 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1106 LA PORTE RD- 5-15-23 I FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE ? INVOICE# 4470 07/07/2023 08/10/2023 2024-00000015 CHARGES $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT DADS PUB,1106 LA PORTE RD,BLDG 1106 LA PORTE RD,WATERLOO/A 50702 �0 DETAILS Inspection Date:05/15/2023 f Inspection Type:Annual Inspection(1Yr) Inspection Number:9241 I Shift: N/A ( Station: N/A Unit: N/A j Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:Install cover plate on outlet. Location:end of bar by TV FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E,F,H,I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1. Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1;1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception:Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector:JEFF SIEBEL-Comments:Install a currently serviced 2A-10BC fire extinguisher in a readily accessible location 4"to 5'above the floor in bar. Location:Not Provided •ENERAL NOTES Printed on 05/16/2023 @ 08:41 Page 1 of 2 JEFF SIEBEL-05/16/2023 @ 08:36 annual fire inspection$ JEFF SIEBEL-05/16/2023 @ 08:38 compressed gas chained and extension cords removed during inspection. REINSPECTION DATE 06/05/2023 CONTACT SIGNATURE Jordan Headington 4 Signed on:05/16/2023 @ 08:38 C ' y INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/16/2023 @ 08:39 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/16/2023 @ 08:41 Page 2 of 2