Loading...
HomeMy WebLinkAbout1425 SA MARNAN DR OF W A TF INVOICE DATE DUE DATE: INVOICE# TOTAL DUE 07/07/2023 08/10/2023 2024-00000020 $80.00 or. 0 11111 11111 1111 11/ • y_ `* 0 a. 4„ ib17�3 Customer#: 14982 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LONGHORN STEAKHOUSE#5374 715 Mulberry St 1425 E SAN MARNAN AV WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1425 SA MARNAN DR- 6-20-23 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price] INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14982 07/07/2023 08/10/2023 2024-00000020 $80.00 Less Prepayment $0.00 Total Due-* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Q- ork,tot WATERLOO FIRE RESCUE \LA INSPECTION REPORT 1040 LONGHORN STEAKHOUSE,1425 E SAN MARNAN DR,BLDG 1125 E SAN MARNAN DR, WATERLOO/A 50702 DETAILS Inspection Date:06/20/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:9122 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3.2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3.Exit access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4,Item 8.4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13, Item 3. Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain overcurrent devices,switching devices or control devices with exit or exit access doors,shall be equipped with panic hardware or fire exit hardware.The doors shall swing in the direction of egress travel. Inspector:JEFF SIEBEL-Comments:repair door hardware. Install permanent signage that states" Push and hold release button below and door to exit" Location: Magnet exit door outside in fenced in area. FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments:Post address in contrasting color to the back ground on the front of the building. Location:front of building. Printed on 06/21/2023 @ 08:59 Page 1 of 3 G r STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguisher Location: By Men's restroom FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEFF SIEBEL-Comments:Fire Alarm inspection report from Johnson Controls dated 10/27/22 lists discrepancies.Contractor must upload corrections online to the compliance engine. Location: Not Provided GENERAL NOTES JEFF SIEBEL-06/21/2023 @ 08:58 annual inspection$80 REINSPECTION DATE 07/11/2023 CONTACT SIGNATURE Caroline Fosselman kitchen Mgr Signed on:06/21/2023 @ 08:55 Ret-ti CGS �.� C' Printed on 06/21/2023 @ 08:59 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL V7ZSigned on:06/21/2023 @ 08:55 QUESTIONS ADOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/21/2023 @ 08:59 Page 3 of 3