COMMERCIAL INSPECTION- 1500 DAVID ST- 6-9-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price]
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
12094 06/23/2023 07/25/2023 2023-00011328 $100.00
Less Prepayment $0.00
Total Due — $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE �PjEA�oo
INSPECTION REPORT tti
A-LINE IRON&METALS INC,1300 DAVID ST,BLDG 1500 DAVID ST,WATERLOO/A 50703
DETAILS
Inspection Date:06/09/2023 j Inspection Type:Annual Inspection(1Yr) Inspection Number:8336 ; Shift: N/A j Station: N/A
Unit: N/A Lead Inspector:JEREMIAH VANDYKE i Other Inspectors: N/A Fee:$100.00
STATUS CODE DESCRIPTION
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEREMIAH VANDYKE-Comments:All Emergency/exit lights need to be
repaired or replaced in building.
Location: Maintenance shop
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEREMIAH VANDYKE-Comments:All Emergency/exit lights need to be
repaired or replaced in building.
Location: Door 8 exit light,pic below.Near cargo trailer.
ME 4
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEREMIAH VANDYKE-Comments:All Emergency/exit lights need to be
repaired or replaced in building.
Location: Maintenance shop
Printed on 06/09/2023 @ 15:28
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector:JEREMIAH VANDYKE-Comments Repair or remove outdoor light.
111111Thiol Location: Docks
Nt
FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device
taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current
taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code.
Inspector:JEREMIAH VANDYKE-Comments: Power tap must be secured.Microwave
`.. must be plugged directly into wall outlet and not into power tap.
t _ _e Location: Located near cargo trailer inside.
Printed on 06/09/2023 @ 15:28
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact. Extension cords shall be used only with portable
t �
:9 -- appliances. Extension cords marked for indoor use shall not be used outdoors
Inspector:JEREMIAH VANDYKE-Comments:Green extension cord cannot be used as
permanent wiring.
:_sue
Location: Located near cargo trailer inside.
Printed on 06/09/2023 @ 15:28
Page 3 of 5
STATUS CODE DESCRIPTION
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
I'- roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection o.f a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEREMIAH VANDYKE-Comments:Holes in ceiling must be repaired with
sheet rock.
Location:Maintenance shop
t
•
•ENERAL NOTES
JEREMIAH VANDYKE-06/09/2023 @ 15:18 Fire Extinguishers serviced/compliant by Pro Shield in May 2023.
JEREMIAH VANDYKE-06/09/2023 @ 15:21 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-06/09/2023 @ 15:21 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-06/09/2023 @ 15:21 Inspection Fee=$100.00
Printed on 06/09/2023 @ 15:28
Page 4 of 5
REINSPECTION DATE
07/09/2023
CONTACT SIGNATURE
Julia Stone Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:06/09/2023 @ 15:19