Loading...
HomeMy WebLinkAbout117 E SAN MARNAN DR F W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4:40 06/23/2023 07/25/2023 2023-00011335 $80.00 u ' o Q 6.3iiiip S 7 v i l7 Customer#: 22784 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable YESWAY 715 Mulberry St 138 CONANT ST WATERLOO, IA 50703 BEVERLY, MA 01915 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 117 E SAN MARNAN DR- 6-1-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22784 06/23/2023 07/25/2023 2023-00011335 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. �ptER� WATERLOO FIRE RESCUE INSPECTION REPORT YESWAY,117 E SAN MARNAN DR,BLDG 117 E SAN MAR/VAN DR,WATERLOO/A 50702 DETAILS Inspection Date:06/01/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:8288 ; Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Inspector:JEFF SIEBEL-Comments: Provide an approved listed oily waste container with self-closing lid or a written corporate policy on how oily materials are safely handled.see attachment Location: Not Provided FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments:remove oil storage to a minimum of 36"clearance to cooking appliance. Location:next to auto-fry FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove all obstructions from in front of electrical panels including oil storage.(it is combustible) Location:back room in front of electrical panel FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Printed on 06/02/2023 @ 10:12 Page 1 of 3 STATUS CODE DESCRIPTION Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood exhaust system cleaning inspection report with all discrepancies corrected. Contractor must upload online to the compliance engine. 166 days past due Location:Not Provided FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system.Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood exhaust system fire suppression inspection report with all discrepancies corrected. Contractor must upload online to the compliance engine. 166 days past due Location: Not Provided FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers. Location: Not Provided GENERAL NOTES JEFF SIEBEL-06/02/2023 @ 10:11 annual inspection$80 REINSPECTION DATE 06/23/2023 Printed on 06/02/2023 @ 10:12 Page 2 of 3 CONTACT SIGNATURE Stephanie Adolph r2c(--, .� Signed on:06/02/2023 @ 10:09 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/02/2023 @ 10:09 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/02/2023 @ 10:12 Page 3 of 3