Loading...
HomeMy WebLinkAbout407 E PARK AVE F WA r INVOICE DATE DUE DATE INVOICE# TOTAL DUE ( 06/23/2023 07/25/2023 2023-00011337 $100.00 o ✓A •f■ff�••r•• •jai b O 3S 7vi7N� Customer#: 9492 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ELK'S CLUB 715 Mulberry St 407 E PARK AV WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -407 E PARK AVE- 5-30-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9492 06/23/2023 07/25/2023 2023-00011337 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT ELK'S CLUB,407E PARK AVE,BLDG 407 E PARK AVE,WATERLOO IA 50703 DETAILS Inspection Date:05/30/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:9182 I Shift: N/A I Station: N/A Unit: N/A ( Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. } Inspector:JEFF SIEBEL-Comments: Remove all storage from egress path and stairs. maintain clearance to fire extinguisher. .11 Location: NE entrance to ballroom stairway FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light by TV monitor. Location:upper kitchen FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light. Location:ceiling by door to old bowling alley. FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light. Location:by elevator and red stag directional sign Printed on 05/31/2023 @ 1012 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit light Location:from stag bar to hall FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit light. Location:bottom of red stag stairs FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEFF SIEBEL-Comments:Annunciator panel has no display.repair display. Last year display was backwards. Location:By Sherri's office FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments: Provide inspection report with all discrepancies corrected .Contractor must upload online to the compliance engine. Location:kitchen hood exhaust cleaning inspection report FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system.Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood fire suppression inspection with all discrepancies corrected .Contractor must upload online to the compliance engine. Location:Ansul system inspection Printed on 05/31/2023 @ 10:12 Page 2 of 4 k STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:Fire extinguishers due for annual service 6/1/23 Location: Not Provided GENERAL NOTES JEFF SIEBEL-05/31/2023 @ 10:12 Annual inspection$100 REINSPECTION DATE 06/21/2023 CONTACT SIGNATURE Jeff Hostettler L- C_ 4_ j, Signed on:05/31/2023 @ 10:09 ,J 6-74 )----/-------___ INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/31/2023 @ 10:09 Printed on 05/31/2023 @ 10:12 Page 3 of 4 .i f s. v QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/31/2023 @ 10:12 Page 4 of 4