COMMERCIAL INSPECTION - 1005 BLACK HAWK RD - 5-31-23 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price J
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
4653 06/21/2023 07/25/2023 2023-00011275 $100.00
Less Prepayment $0.00
Total Due— $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE 405ERtoo
INSPECTION REPORT 1 t
BLACK HAWK TENNIS CLUB,100S BLACK HAWK BLD&1005 BLACK HAWK RD,WATERLOO
IA 50T01 4241021
DETAILS
Inspection Date:05/31/2023 Inspection Type:Annual Inspection(1Yr) ; Inspection Number:7812 Shift: N/A i Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A
---t1\GO
STATUS CODE DESCRIPTION
FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire
force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force
open doors. required to retract latch bolts or disengage other devices that hold the door in a
closed position. For other swinging doors,as well as sliding and folding doors,the
door latch shall release when subjected to a 15-pound(67 N)force.The door shall be
set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a
full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch
doors shall comply with the following: 1.Where door hardware operates by push or
pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).
2.Where door hardware operates by rotation,the operational force to unlatch the
door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall
comply with the following: 1.For interior swinging egress doors that are manually
operated,other than doors required to be fire rated,the force for pushing or pulling
open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding
doors or folding doors,and doors required to be fire rated,the door shall require
not more than a 30-pound(133 N)force to be set in motion and shall move to a full-
open position when subjected to not more than a 15-pound(67 N)force.
Inspector:JEFF SIEBEL-Comments: Exit door must open with less than 15#force.
Remove obstructions from outside door(brush and trees).
Location:Exit door to East#3 Court
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments:Solid panel in front of exit door.RE-Install
reflective strip panels in front of exit door.
Location: Indoor tennis court#5
Printed on 06/01/2023 @ 09:24
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector:JEFF SIEBEL-Comments:properly mount electrical box that is ripped off of
post.
Location:outside tennis court#5
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact. Extension cords shall be used only with portable
appliances. Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:remove extension cord to cooler in building.
Install permanent outlet with permits and inspections.Cooler must plug directly into
wall outlet.
Location: Beer garden concession
FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a
clothes dryer shall be maintained in accordance with the manufacturer's operating
instructions to prevent the accumulation of lint or debris that prevents the exhaust
of air and products of combustion.
Inspector:JEFF SIEBEL-Comments:Provide documentation of dryer vent cleaning to
the outside of the building with signature and date.
Location:upstairs
FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view.In rooms
unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be
provided to indicate the locations of extinguishers.
Inspector:JEFF SIEBEL-Comments:Genie lift is blocking fire extinguisher.relocate lift
or extinguisher and sign.
Location: Indoor tennis court 5
Printed on 06/01/2023 @ 09:24
Page 2of3
b
STATUS CODE DESCRIPTION
FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on
the hangers or brackets supplied. Hangers or brackets shall be securely anchored to
the mounting surface in accordance with the manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:properly hang fire extinguisher in office 4"to 5'
above the floor.
Location:upstairs office
GENERAL NOTES
JEFF SIEBEL-06/01/2023 @ 08:37 annual inspection$100
REINSPECTION DATE
06/23/2023
CONTACT SIGNATURE
Chris Sagers
Signed on:06/01/2023 @ 09:22 ((c/ L C ��
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:06/01/2023 @ 09:23