Loading...
HomeMy WebLinkAbout1005 BLACK HAWK RD W q T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 06/21/2023 07/25/2023 2023-00011275 $100.00 u / Customer#: 4653 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BLACK HAWK TENNIS CLUB 715 Mulberry St PO BOX 26 WATERLOO, IA 50703 WATERLOO, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1005 BLACK HAWK RD - 5-31-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4653 06/21/2023 07/25/2023 2023-00011275 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 405ERtoo INSPECTION REPORT 1 t BLACK HAWK TENNIS CLUB,100S BLACK HAWK BLD&1005 BLACK HAWK RD,WATERLOO IA 50T01 4241021 DETAILS Inspection Date:05/31/2023 Inspection Type:Annual Inspection(1Yr) ; Inspection Number:7812 Shift: N/A i Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A ---t1\GO STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments: Exit door must open with less than 15#force. Remove obstructions from outside door(brush and trees). Location:Exit door to East#3 Court FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:Solid panel in front of exit door.RE-Install reflective strip panels in front of exit door. Location: Indoor tennis court#5 Printed on 06/01/2023 @ 09:24 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:JEFF SIEBEL-Comments:properly mount electrical box that is ripped off of post. Location:outside tennis court#5 FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove extension cord to cooler in building. Install permanent outlet with permits and inspections.Cooler must plug directly into wall outlet. Location: Beer garden concession FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEFF SIEBEL-Comments:Provide documentation of dryer vent cleaning to the outside of the building with signature and date. Location:upstairs FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view.In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:Genie lift is blocking fire extinguisher.relocate lift or extinguisher and sign. Location: Indoor tennis court 5 Printed on 06/01/2023 @ 09:24 Page 2of3 b STATUS CODE DESCRIPTION FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:properly hang fire extinguisher in office 4"to 5' above the floor. Location:upstairs office GENERAL NOTES JEFF SIEBEL-06/01/2023 @ 08:37 annual inspection$100 REINSPECTION DATE 06/23/2023 CONTACT SIGNATURE Chris Sagers Signed on:06/01/2023 @ 09:22 ((c/ L C �� INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/01/2023 @ 09:23 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/01/2023 @ 09:24 Page 3 of 3