Loading...
HomeMy WebLinkAbout1050 FLAMMANG DR O W q Tk• INVOICE DATE DUE DATE INVOICE# TOTAL DUE x. �( 06/21/2023 07/25/2023 2023-00011281 $100.00 u.,rrrire; j O ) o 6.4S 7vt7N� Customer#: 20707 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LEGACY MANOR 715 Mulberry St 3408 WOODLAND AVE#504 WATERLOO, IA 50703 WEST DES MOINES, IA 50266 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1050 FLAMMANG DR- 5-23-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price j INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20707 06/21/2023 07/25/2023 2023-00011281 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUECP1 ,:oINSPECTION REPORT zo LEGACY MANOR,1050 FLAMMANG DR,BLDG 1050 FLAMMANG DR,WATERLOO IA 50702 DETAILS Inspection Date:05/23/2023 j Inspection Type:Residential Common Areas Inspection I Inspection Number:8255 I Shift: N/A Station: N/A I Unit: N/A Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1032.4-Exit signs. Exit signs shall be installed and maintained in accordance with the building code that was in effect at the time of construction and the applicable provisions in Section 1104. Decorations,furnishings,equipment or adjacent signage that impairs the visibility of exit signs,creates confusion or prevents identification of the exit shall not be allowed. Inspector:JEREMIAH VANDYKE-Comments: Broken light on Exit light.Send picture after repaired. Location: East stair tower on 1st floor. FAIL 1104.5-Illumination Where means of egress illumination is provided,the power supply for means of emergency power. egress illumination shall normally be provided by the premises'electrical supply. In the event of power supply failure,illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 1.Group A having 50 or more occupants. Exception: Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height,buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories.4.Group F having more than 100 occupants. Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code. 5.Group I.6.Group M. Exception: Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines.7.Group R-1. Exception: Where each sleeping unit has direct access to the outside of the building at grade. 8.Group R-2. Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Inspector:JEREMIAH VANDYKE-Comments: Emergency egress light tested and failed. Send picture of button being pushed of light working. Location: Main entrance by Office#117. Printed on 05/23/2023 @ 16:00 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 901.6-Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems,mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. Inspector:JEREMIAH VANDYKE-Comments:Will send pictures or corrected violations. Location:Not Provided FAIL 99999-Inspection Outcome Did the inspection pass or fail? Inspector:JEREMIAH VANDYKE-Comments:Will send pictures of corrected violations. Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-05/23/2023 @ 15:55 Fire extinguishers serviced/compliant by Midwest Alarm in January 2023. JEREMIAH VANDYKE-05/23/2023 @ 15:56 All clothes dryers were cleaned in 7/26/2022 that was contracted out.Will start doing in house cleaning and maintaining cleaning log. JEREMIAH VANDYKE-05/23/2023 @ 15:57 01/26/2023 S-(Annual)Fire Alarm MIDWEST ALARM SERVICES Reviewed Compliant JEREMIAH VANDYKE-05/23/2023 @ 15:57 11/22/2022 S-(Annual)Fire Sprinkler TRI-STATE AUTOMATIC SPRINKLER,INC.Reviewed Compliant JEREMIAH VANDYKE-05/23/2023 @ 15:58 Discussed lithium batteries and Ev's. JEREMIAH VANDYKE-05/23/2023 @ 15:58 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/23/2023 @ 15:58 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- Printed on 05/23/2023 @ 16:00 Page 2 of 3 GENERAL NOTES JEREMIAH VANDYKE-05/23/2023 @ 15:58 Inspection Fee=$100.00 REINSPECTION DATE 06/22/2023 CONTACT SIGNATURE Lisa Timm Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:05/23/2023 @ 16:00 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 05/23/2023 @ 16:00 Page 3of3