Loading...
HomeMy WebLinkAbout45 W JEFFERSON ST OF Wq TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 'e 06/21/2023 07/25/2023 2023-00011286 $100.00 O )a�s , o 7vil Customer#: 23124 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GRAND CROSSING APARTMENTS 715 Mulberry St 45 W JEFFERSON ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -45 W JEFFERSON ST- 5-22-23 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price j INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23124 06/21/2023 07/25/2023 2023-00011286 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE ; INSPECTION REPORT GRAND CROSSING,45 WJEFFERSON ST,BLDG 45 W JEFFERSON,WATERLOO IA 50702 DETAILS Inspection Date:05/22/2023 ; Inspection Type: Residential Common Areas Inspection Inspection Number: 10284 Shift: N/A ; Station: N/A j Unit: N/A Lead Inspector:JEREMIAH VANDYKE ( Other Inspectors: N/A ; Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments:Generator report/maintenance needed of last inspection by contractor. Location: Not Provided FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments: Fire alarm in trouble mode and must be addressed by licensed fire alarm contractor. Location:3rd floor coffee room on Fire alarm panel. FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments:Smoke alarm pulled from ceiling and hanging by wires. Location: Near room#401 FAIL 308.1.4-Open-flame cooking Charcoal burners and other open-flame cooking devices shall not be operated on devices. combustible balconies or within 10 feet(3048 mm)of combustible construction. Exceptions: 1.One-and two-family dwellings.2.Where buildings,balconies and decks are protected by an automatic sprinkler system.3.LP-gas cooking devices having LP- gas container with a water capacity not greater than 21/2 pounds[nominal 1 pound (0.454 kg)LP-gas capacity]. Inspector:JEREMIAH VANDYKE-Comments: 1.Multiple balconies had Charcoal grills. 2.20 lb.LP gas were on multiple balconies. Location:Balconies Printed on 05/22/2023 @ 15:46 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments:All clothes dryers must be cleaned and either record log of cleaning/or invoice must be provided. Location:All clothes dryers. FAIL 703.1 -Maintaining Materials and firestop systems used to protect membrane and through penetrations protection. in fire-resistance-rated construction and construction installed to resist the passage of smoke shall be maintained.The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Hole in ceiling must be repaired located on corner mechanical room.Will send picture of repair. Location:Corner mechanical room FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEREMIAH VANDYKE-Comments:Door needs to close and latch automatically. Location: East stair tower 1st floor. FAIL 99999-Inspection Outcome Did the inspection pass or fail? Inspector:JEREMIAH VANDYKE-Comments:Will send pictures/videos/reports of corrected violations. Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-05/22/2023 @ 15:44 Discussed lithium batteries/EV's. JEREMIAH VANDYKE-05/22/2023 @ 15:45 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. Printed on 05/22/2023 @ 15:46 Page 2 of 4 GENERAL NOTES JEREMIAH VANDYKE-05/22/2023 @ 15:45 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/22/2023 @ 15:45 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-05/22/2023 @ 15:45 Inspection Fee=$100.00 JEREMIAH VANDYKE-05/22/2023 @ 15:01 Fire extinguishers serviced/compliant by Superior Fire in February 2022. JEREMIAH VANDYKE-05/22/2023 @ 15:39 02/01/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-05/22/2023 @ 15:39 11/09/2022 S-5 Year Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS,INC.Reviewed Compliant JEREMIAH VANDYKE-05/22/2023 @ 15:39 10/20/2022 S-(Annual)Fire Pump BLACKHAWK AUTOMATIC SPRINKLERS,INC.Reviewed Compliant JEREMIAH VANDYKE-05/22/2023 @ 15:40 10/20/2022 S-Private Fire Hydrants BLACKHAWK AUTOMATIC SPRINKLERS,INC. Reviewed Compliant REINSPECTION DATE 06/21/2023 CONTACT SIGNATURE Chris Olsen Reason for not collecting a signature: NA Printed on 05/22/2023 @ 15:46 Page 3 of 4 INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:05/22/2023 @ 15:38 /117 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 05/22/2023 @ 15:46 Page 4 of 4