COMMERCIAL INSPECTION - 2608 UNIVERSIITY AVE- 6-9-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price J
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
4068 06/22/2023 07/25/2023 2023-00011309 $100.00
Less Prepayment $0.00
Total Due — $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
,1Cc
WATERLOO FIRE RESCUE 4,„ER`oo
IIAD
INSPECTION REPORT
MAPLE LANES,2608 UNIVERSITY AVE,BLDG 2608 UNIVERSITY AVE,WATERLOO/A 50701 4740
DETAILS
Inspection Date:06/09/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:8643 Shift: N/A I Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A r�
�1
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
4
means of egress.
:
Inspector:JEFF SIEBEL-Comments: Remove ALL storage from stairwell to game room
i11111r- upstairs and downstairs.Repeat violation. Recommend Permanent No Storage
signage.
Location:stair well to upstairs game room
FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no
and maintenance troubles,supervisory,or alarms)?
Inspector:JEFF SIEBEL-Comments:fire alarm pull station falling off wall.Secure back
to wall.
Location: By NW exit by fire sprinkler riser room.
Printed on 06/12/2023 @ 14:00
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system
equipment to permit immediate safe operation and maintenance of such equipment.
Storage,trash and other materials or objects shall not be placed or kept in such a
manner that would prevent such equipment from being readily accessible.
10
Inspector:JEFF SIEBEL-Comments:remove obstructions. maintain a minimum of 36"
'"` clearance at all times.
` *1.-
*10, ‘ -
s Location:fire sprinkler riser room
'- -...1 '-'
...., . __. _
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
`� A Inspector:JEFF SIEBEL-Comments:Remove non-grounded extension cord to pinball
_' - - machine with ground.
. Location: Loft Game Room Pinball area.
Printed on 06/12/2023 @ 14:00
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings, nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
appliances. Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments: Remove extension cords to 3 freezers. Freezers
must plug directly into wall outlet. Install permanent power with permits and
inspections.
Location: Basemen storage area
FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3.
Inspector:JEFF SIEBEL-Comments:provide documentation of kitchen hood cleaning
inspection with all violations corrected.contractor must post online to the
compliance engine.
Location: kitchen
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned, properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:Provide annual service for fire extinguishers.pro-
shop was 2019 others were 2022.
Location: Pro shop and rest of building
GENERAL NOTES
JEFF SIEBEL-06/12/2023 @ 13:55 annual inspection$100
Printed on 06/12/2023 @ 14:00
Page 3 of 4
REINSPECTION DATE
06/30/2023
CONTACT SIGNATURE
Rich Eighme ( L
Signed on:06/12/2023 @ 13:55 /( Li t
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:06/12/2023 @ 13:55