COMMERCIAL INSPECTION-214 WASHINGTON ST- 5-23-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price]
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
13418 06/22/2023 07/25/2023 2023-00011313 $100.00
Less Prepayment $0.00
Total Due $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
l ..
WATERLOO FIRE RESCUE
INSPECTION REPORT
BRIDGES SENIOR LIFESTYLE LIVING,214 WASHINGTON ST,BLDG 214 WASHINGTON ST,
WATERLOO/A S0702 4114;0
DETAILS
Inspection Date:05/23/2023 Inspection Type: Residential Common Areas Inspection j Inspection Number: 10299 Shift: N/A
Station: N/A Unit: N/A ' Lead Inspector:JEREMIAH VANDYKE j Other Inspectors: N/A ; Fee:$100.00
STATUS CODE DESCRIPTION
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEREMIAH VANDYKE-Comments:Open electrical box needs to be capped
or plate installed.
Location: 11th floor east back stair tower above door leading into hallway.
FAIL 603.4.1 -Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and
legible sign stating"ELECTRICAL ROOM"or similar approved wording.The
disconnecting means for each service,feeder or branch circuit originating on a
switchboard or panelboard shall be legibly and durably marked to indicate its
purpose unless such purpose is clearly evident.Where buildings or structures are
supplied by more than one power source,markings shall be provided at each service
equipment location and at all interconnected electric power production sources
identifying all electric power sources at the premises in accordance with NFPA 70.
Inspector:JEREMIAH VANDYKE-Comments:Signage needed on main electrical
shutoff stating"Building Main Electrical Disconnect".
Location: Main electrical panel.
FAIL 99999-Inspection Outcome Did the inspection pass or fail?
Inspector:JEREMIAH VANDYKE-Comments:Will send pictures of corrected violations.
Location:Not Provided
GENERAL NOTES
JEREMIAH VANDYKE-05/23/2023 @ 15:30 Fire extinguishers serviced/compliant by Pro shield in October 2022.
JEREMIAH VANDYKE-05/23/2023 @ 15:31 Clothes Dryer record log of last cleaning in house is 1/5/2023.
Printed on 05/23/2023 @ 15:47
Page 1 of 3
GENERAL NOTES
JEREMIAH VANDYKE-05/23/2023 @ 15:31 Generator report completed by HM Cragg on 3/21/2023.
JEREMIAH VANDYKE-05/23/2023 @ 15:33 Emergency generator weekly test completed 5/23/2023 in house recorded log.
JEREMIAH VANDYKE-05/23/2023 @ 15:33 Fire Pump in house record log completed 5/2/2023.
JEREMIAH VANDYKE-05/23/2023 @ 15:37 Discussed lithium batteries/EV's.
JEREMIAH VANDYKE-05/23/2023 @ 15:43 04/21/2023 S-Kitchen Hood Suppression PROSHIELD FIRE&SECURITY Reviewed
Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:44 02/28/2023 S-(Semi-Annual)Kitchen Exhaust AKA SERVICES INC. Reviewed Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:44 10/12/2022 S-5 Year Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS,INC.Reviewed
Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:44 10/12/2022 R-Standpipe Deficiency Repair BLACKHAWK AUTOMATIC SPRINKLERS,INC.
Reviewed Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:45 10/04/2022 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC.
Reviewed Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:45 10/04/2022 S-(Annual)Fire Alarm HAWKEYE COMMUNICATION Reviewed Compliant
JEREMIAH VANDYKE-05/23/2023 @ 15:46 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-05/23/2023 @ 15:46 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-05/23/2023 @ 15:46 Inspection Fee=$100.00
Printed on 05/23/2023 @ 15:47
Page 2of3
REINSPECTION DATE
06/22/2023
CONTACT SIGNATURE
Ben Gardner Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:05/23/2023 @ 15:37 J/ / A