HomeMy WebLinkAbout1104 WASHINGTON ST o WA .F� INVOICE DATE DUE DATE INVOICE# TOTAL DUE
p 06/22/2023 07/25/2023 2023-00011315
I o $80.00
0
Customer#: 14228
Please Make Check Payable and Remit To:
City of Waterloo
A TTN: City Clerk/Accounts Receivable
KWIK STOP#3 715 Mulberry St
1104 WASHINGTON ST WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION- 1104 WASHINGTON ST- 6-1-23
FOR BILLING INQUIRY: (319)291-4323 I
LDescription
Total Price J
INSPECTION 2,000
OCCUPANCY FEE $70.00
$10.00
CUSTOMER# BILLING DATE I
DUE DATE INVOICE# CHARGES
14228 06/22/2023
07/25/2023 I 2023-00011315
$80.00
Less Prepayment $0.00
Total Due—* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collectionsof
cent
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE �P�Entoo
INSPECTION REPORT
KWIK STOP 3 1104 WASHINGTON ST,BLDG 1104 WASHINGTON ST-, STE A, WATERLOO/A
50702 4%10
DETAILS
Inspection Date:06/01/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8523 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A i Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments:Remove all obstructions and storage to back door
or appeal to building official Greg Ahlhelm to remove requirement for exit and
it
signage.
Location:back exit hall
lay
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit/egress light abovefront door.
Location:front door
Printed on 06/02/2023 @ 11:23
Page 1 of 2
STATUS CODE DESCRIPTION
FM L 603.4-Working space and A working space of not Working space around electrical equipment shall be provided
clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000
volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000
volts.The minimum required working space shall be not less than 30 inches(762 mm)
in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the electrical service
equipment is wider than 30 inches(762 mm),the minimum working space shall be
_ not less than the width of the equipment.Storage of materials shall not be located
within the designated working space.Exceptions: 1.Where other dimensions are
4 required or allowed by NFPA 70.2.Access openings into attics or under-floor areas
that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments: Remove all obstructions to electrial panels
oak—
including 2 coolers.
Location:back room
GENERAL NOTES
JEFF SIEBEL-06/02/2023 @ 11:21 annual inspection$80
REINSPECTION DATE
06/26/2023
CONTACT SIGNATURE
Mohammad ILYAS /
Signed on:06/02/2023 @ 11:21 c / 7
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:06/02/2023 @ 11:21
QUESTIONS ASOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 06/02/2023 @ 11:23
Page 2 of 2