Loading...
HomeMy WebLinkAbout202 E 1ST ST W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0A. � 06/22/2023 07/25/2023 2023-00011317 $80.00 o ow- 6- ivilN Customer#: 20693 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable FRATERNAL ORDER OF EAGLES 715 Mulberry St 202 E 1ST ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -202 E 1ST ST- 6-15-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20693 06/22/2023 07/25/2023 2023-00011317 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 3 WATERLOO FIRE RESCUE 0093 40._,ER,00 INSPECTION REPORT FRATERNAL ORDER OF EAGLES ARIE#7 64,202E1STST,BLDG202E1STST,WATERLOO/A 50703 DETAILS Inspection Date:06/15/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:8201 I Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:replace missing outlet cover on stage. Location:Stage FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove extension cord to pool table light. Location: Pool Table Light FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Inspector:JEFF SIEBEL-Comments: Provide documentation of kitchen hood exhaust cleaning inspection report with all discrepancies corrected.Contractor must upload online to the compliance engine. Location:kitchen Printed on 06/16/2023 @ 09:24 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. Location: Not Provided GENERAL NOTES JEFF SIEBEL-06/16/2023 @ 09:13 Corrected during inspection:A.obstructions to electrical panel moved B.compressed gas cylinders chained. JEFF SIEBEL-06/16/2023 @ 09:13 annual inspection$80 REINSPECTION DATE 07/06/2023 CONTACT SIGNATURE Jeff Murphy-Trustee Signed on:06/16/2023 @ 09:14 i7 ,( C CI ici, --/\/ Printed on 06/16/2023 @ 09:24 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/16/2023 @ 09:14 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/16/2023 @ 09:24 Page 3 of 3