Loading...
HomeMy WebLinkAbout428 E 1ST ST O WA r INVOICE DATE DUE DATE INVOICE# TOTAL DUE �0 06/22/2023 07/25/2023 2023-00011318 $80.00 )144040. S7vt ) Customer#: 12631 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOLLAR GENERAL 715 Mulberry St 100 MISSION RIDGE WATERLOO, IA 50703 GOODLETTSVILLE, TN 37072 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-428 E 1ST ST- 5-11-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12631 06/22/2023 07/25/2023 2023-00011318 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. • WATERLOO FIRE RESCUE �ptER o INSPECTION REPORT 411:;‘ DOLLAR GENERAL,428 E 1ST ST,BLDG 428 E 1ST ST,WATERLOO IA 50703 DETAILS Inspection Date:05/11/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number: 10210 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a � ..' means of egress. ittr Inspector:JEREMIAH VANDYKE-Comments:All storage is to be cleared in marked exit paths. Location: Not Provided FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. „ - Inspector:JEREMIAH VANDYKE-Comments:All storage is to be cleared in marked exit paths. a : Location: Not Provided iasiAtEffitla t _ FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEREMIAH VANDYKE-Comments:Master key needed for Knox box.Will call Fire Inspector when key is available. Location: Not Provided Printed on 05/11/2023 @ 09:49 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or �-. roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the `' intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the t3 te, intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints an d * _ voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Ceiling Tiles missing and need replaced located: 1.Employee break room.2.Back merchandise storage/dock area.3.Back merchandise storage Office room. Location: Not Provided FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.joints in smoke barriers.3.Voids at the intersection of a = horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the A' _ intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Ceiling Tiles missing and need replaced located: 1.Employee break room.2.Back merchandise storage/dock area.3.Back merchandise storage Office room. Location: Not Provided Printed on 05111/2023 @ 09:49 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the • intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Ceiling Tiles missing and need replaced located: 1.Employee break room.2.Back merchandise storage/dock area.3.Back merchandise storage Office room. Location: Not Provided FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and 717/ unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble si uishers shall be installed inside of a f signal.2.3.The extinguishers r building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance ;if is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:Fire extinguisher missing and needs replaced near employee break room. Location: Not Provided FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEREMIAH VANDYKE-Comments: Blocked fire extinguisher located on east wall. Location: Not Provided Printed on 05/11/2023 C.09:49 Page 3of5 GENERAL NOTES JEREMIAH VANDYKE-05/11/2023 @ 09:47 Fire Extinguishers compliant/serviced by Bell's Fire Stop in April 2023. JEREMIAH VANDYKE-05/11/2023 @ 09:47 No Sprinkler or Fire alarm in building. JEREMIAH VANDYKE-05/11/2023 @ 09:48 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-05/11/2023 @ 09:48 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/11/2023 @ 09:48 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-05/11/2023 @ 09:48 Inspection Fee=$80.00 REINSPECTION DATE 06/10/2023 CONTACT SIGNATURE Taya Harris Contact Refused Refusal Reason:N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE Lin)/v— Signed on:05/11/2023 @ 09:36 Printed on 05/11/2023 @ 09:49 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 05/11/2023 @ 09:49 Page 5of5