Loading...
HomeMy WebLinkAbout610 E 4TH ST OF WA 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,� ` r< 06/22/2023 07/25/2023 2023-00011320 $100.00 u !rg O b O 3 S 1V%') Customer#: 11098 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable RENAISSANCE PARK APT 715 Mulberry St 610E 4TH ST WATERLOO, IA 50703 WATAERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 610 E 4TH ST- 5-9-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11098 06/22/2023 07/25/2023 2023-00011320 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE44021 ,4 INSPECTION REPORT f \ RENAISSANCE PARK APARTMENTS,610 E 4TH ST,BLDG 610 E 4TH ST,WATERLOO IA 50703 DETAILS Inspection Date:05/09/2023 Inspection Type: Residential Common Areas Inspection Inspection Number:8218 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEREMIAH VANDYKE-Comments: Picnic table to be removed located between sheds in back due to emergency exit path. Location: Not Provided FAIL 1032.4-Exit signs. Exit signs shall be installed and maintained in accordance with the building code that was in effect at the time of construction and the applicable provisions in Section 1104. Decorations,furnishings,equipment or adjacent signage that impairs the visibility of exit signs,creates confusion or prevents identification of the exit shall not be allowed. Inspector:JEREMIAH VANDYKE-Comments:Exit signs tested and failed located: 1.1st floor main entrance.2.Near apartment#63.3.Near apartment#43.4.Near apartment#33. Location: Not Provided Printed on 05/09/2023 @ 14:50 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1104.5-Illumination Where means of egress illumination is provided,the power supply for means of emergency power. egress illumination shall normally be provided by the premises'electrical supply. In the event of power supply failure,illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 1.Group A having 50 or more occupants. Exception: Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height,buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories.4.Group F having more than 100 occupants. Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code. 5.Group I.6.Group M.Exception:Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines.7.Group R-1. Exception: Where each sleeping unit has direct access to the outside of the building at grade. 8.Group R-2.Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Inspector:JEREMIAH VANDYKE-Comments: Emergency Exit lights tested and failed, located: 1.1st floor public bathroom.2.1st floor south stair tower.3.North stair tower landing between 3rd and 4th floor.4.North stair tower between 5th and 6th floor.5.South stair tower between 2nd and 3rd floor. Location: Not Provided FAIL 315.3.2-Means of egress. Combustible materials shall not be stored in exits or enclosures for stairways and ramps.Combustible materials in the means of egress during construction, demolition,remodeling or alterations shall comply with Section 3312.3. Inspector:JEREMIAH VANDYKE-Comments:Storage in south stair tower on 1st floor under steps need to be removed. Location: Not Provided FAIL 610.1.2-Maintenance. The lint trap, mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments:Records log of cleaning needed with dates and name. Location: Not Provided Printed on 05/09/2023 @ 14:50 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 703.1 -Maintaining Materials and firestop systems used to protect membrane and through penetrations protection. in fire-resistance-rated construction and construction installed to resist the passage of smoke shall be maintained.The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Trash chute room door missing on 5th floor and must be replaced. Location: Not Provided FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments: 1.Ceiling tile missing on 1st floor near restrooms. Location: Not Provided FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEREMIAH VANDYKE-Comments: Doors not closing and latching properly, located: 1.Door leading from hallway into residence community room on 1st floor.2. Dumpster room walk in door.3.South stair tower door 2nd floor.4.North stair tower door 5th floor. Location: Not Provided FAIL 99999-Inspection Outcome Did the inspection pass or fail? Inspector:JEREMIAH VANDYKE-Comments: None Location: Not Provided GENERAL NOTES Printed on 05/09/2023 @ 14:50 Page 3of5 JEREMIAH VANDYKE-05/09/2023 @ 14:10 Fire Extinguisher serviced/compliant by Pro-shield in September 2022. JEREMIAH VANDYKE-05/09/2023 @ 14:45 03/23/2023 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS,INC. Reviewed Compliant JEREMIAH VANDYKE-05/09/2023 @ 14:46 06/24/2022 S-(Annual)Fire Alarm COMMUNITY ELECTRIC/PRIMARY SYSTEMS Reviewed Compliant JEREMIAH VANDYKE-05/09/2023 @ 14:47 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-05/09/2023 @ 14:47 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/09/2023 @ 14:47 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-05/09/2023 @ 14:47 Inspection Fee=$100.00 REINSPECTION DATE 06/08/2023 CONTACT SIGNATURE Ashley Taylor Contact Refused Refusal Reason:N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:05/09/2023 @ 14:50 Printed on 05/09/2023 @ 14:50 Page 4of5 . QUESTIONS AIOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 05/09/2023 @ 14:50 Page 5 of 5