Loading...
HomeMy WebLinkAbout1501 E SAN MARNAN DR O W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE "P0 06/22/2023 07/25/2023 2023-00011303 $610.00 to Oe 3S 7V17`� Customer#: 4661 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable TARGET STORE T1792 715 Mulberry St PO BOX 111 WATERLOO, IA 50703 MINNEAPOLIS, MN 55440 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1501 E SAN MARNAN DR- 5-23-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price j INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4661 06/22/2023 07/25/2023 2023-00011303 $610.00 Less Prepayment $0.00 Total Due—* $610.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 4AP?ER1-o0 INSPECTION REPORT TARGET SUPER STORE,1501 E SAN MARNAN DR,BLDG 1501 E SAN MARNAN DR,WATERLOO IA 50702 DETAILS Inspection Date:05/23/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:9644 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A Fee:$610.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments: Remove obstructions from exit path. Path must be kept clear at all times and not used for storage. Location: Former Employees exit FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:A. Provide documentation of testing and repair of all egress and exit lights with all discrepancies corrected with signature and date.B. Provide current annual generator engine service report and a current load bank test or documentation of monthly testing in accordance with NFPA standards. Location:A.emergency Lighting B.Generator FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Inspector:JEFF SIEBEL-Comments: Provide approved listed oily waste receptacle for all grease laden materials. Location: Not Provided Printed on 05/24/2023 @ 09:01 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments:Remove storage,obtain a minimum of 36" clearance to gas water heater. Location: Front Janitor Closet FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments: Remove all storage and combustible materials sz from top of charging station for floor scrubbers. Location:maintenance area FAIL 5.2.1.1.5-Missing Escutcheons and coverplates for recessed,flush,and concealed sprinklers shall be escutcheons replaced if found missing during the inspection. Inspector:JEFF SIEBEL-Comments:replace missing fire sprinkler escutcheon. Location:OPU Cooler FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments: Install permanent sign above obstructions and visible down hall ways stating"Fire Sprinkler Riser Room"in back storage area. Location: Back storage area Printed on 05/24/2023 @ 09:01 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments: Install permanent sign above obstructions stating "Fire Department Connection"or"FDC" Location:Outside back of store above fire department connection FAIL 705.2-Inspection and Opening protectives in fire-resistance-rated assemblies shall be inspected and maintenance. maintained in accordance with NFPA 80.Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105.Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked,obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. Inspector:JEFF SIEBEL-Comments: Fire door propped open and blocked with table. Fire Doors to remain operational at all times. Location:fixture room FAIL 903.3.1 -Standards. Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEFF SIEBEL-Comments: Install proper zone maps to match fire sprinkler riser coverage. Location:fire department riser room FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system.Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire suppression inspection report with all discrepancies corrected.Currently 103 days past due.Contractor must upload online to the compliance engine. Location: Not Provided Printed on 05/24/2023 @ 09:01 Page 3 of 5 i STATUS CODE DESCRIPTION FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:mount fire extinguisher 4"to 5'above the floor in a readily accessible location. Location: Front stock room GENERAL NOTES JEFF SIEBEL-05/23/2023 @ 15:44 annual inspection$610. JEFF SIEBEL-05/24/2023 @ 08:25 Hood cleaning due 7/20/23 JEFF SIEBEL-05/24/2023 @ 08:29 Fire sprinkler and private fire hydrant inspections due 6/15 JEFF SIEBEL-05/24/2023 @ 08:31 Fire alarm inspection due 6/9 JEFF SIEBEL-05/24/2023 @ 08:33 Fire Inspection completed during major renovation.Other items handled at final fire building inspection. REINSPECTION DATE 06/13/2023 CONTACT SIGNATURE Griffen Cameron Maint 2023 Signed on:05/24/2023 @ 08:31 Q C. C:7; , INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/24/2023 @ 08:31 1, Printed on 05/24/2023 @ 09:01 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/24/2023 @ 09:01 Page 5 of 5