Loading...
HomeMy WebLinkAbout627 sycamore st W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE "P0 06/22/2023 07/25/2023 2023-00011306 $100.00 O •`rii ii\rrrrrrrrr rrr r • i I O 3 ?t�17, Customer#: 23174 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MARSH PLACE APARTMENTS -COMMERCIAL 715 Mulberry St 845 31ST AVE SW WATERLOO, IA 50703 CEDAR RAPIDS, IA 52404 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 627 SYCAMORE ST- 5-18-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price j INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23174 06/22/2023 07/25/2023 2023-00011306 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. C F WA TERL 00 FIRE RESCUE 40SER[0 0 INSPECTION REPORT `N MARSH PLACE APARTMENTS,627 SYCAMORE ST,BLDG 627 SYCAMORE-STE 2-6 FLOOR, WATERLOO IA 50703 44110 DETAILS Inspection Date:05/18/2023 ( Inspection Type:Residential Common Areas Inspection I Inspection Number:7947E Shift: N/A Station: N/A ! Unit: N/A ; Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A ; Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1032.4-Exit signs. Exit signs shall be installed and maintained in accordance with the building code that was in effect at the time of construction and the applicable provisions in Section 1104. Decorations,furnishings,equipment or adjacent signage that impairs the visibility of exit signs,creates confusion or prevents identification of the exit shall not be allowed. Inspector:JEREMIAH VANDYKE-Comments: Exit light tested and failed.Will send video/picture of working properly. Location: Near room#202 FAIL 1104.16.5.1 -Examination. Fire escape stairways and balconies shall be examined for structural adequacy and safety in accordance with Section 1104.16.5 by a registered design professional or others acceptable to the fire code official every 5 years,or as required by the fire code official.An inspection report shall be submitted to the fire code official after such examination. Inspector:JEREMIAH VANDYKE-Comments:Need copy of last fire escape inspection. Send via email tojeremiah.vandyke@waterloo-ia.org. Location: Not Provided Printed on 05/18/2023 @ 16:08 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1104.5-Illumination Where means of egress illumination is provided,the power supply for means of emergency power. egress illumination shall normally be provided by the premises'electrical supply. In the event of power supply failure,illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 1.Group A having 50 or more occupants. Exception: Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height,buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories.4.Group F having more than 100 occupants. Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code. 5.Group I.6.Group M.Exception: Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines.7.Group R-1. Exception: Where each sleeping unit has direct access to the outside of the building at grade. 8.Group R-2.Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Inspector:JEREMIAH VANDYKE-Comments:Egress on 5th street side tested and failed.Will send video/picture of working properly. Location:Suite C FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEREMIAH VANDYKE-Comments:Unsure if there were any master key changes. Please respond via email if no changes to email. Location: Not Provided FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments:2 signs needed.Located: 1.On main floor leading into basement with sign stating, "FACP&Sprinkler Riser".2.In basement at bottom of steps with sign stating"FACP panel to the right"and "Main electrical panel to the left".Paper sign found on ground.ALL signs to be made of durable materials, permanently installed and readily visible. Location:Not Provided Printed on 05/18/2023 @ 16:08 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEREMIAH VANDYKE-Comments: None Location: Basement 4\` fy FAIL 610.1.2-Maintenance. The lint trap, mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments:Record log needed for all Clothes dryer cleanings in building. Location: Not Provided FAIL 99999-Inspection Outcome Did the inspection pass or fail? Inspector:JEREMIAH VANDYKE-Comments:None Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-05/18/2023 @ 15:49 Fire Extinguishers serviced/compliant by Proshield in August 2022. JEREMIAH VANDYKE-05/18/2023 @ 15:49 03/22/2023 S-(Annual)Fire Sprinkler CONTINENTAL FIRE SPRINKLER Reviewed Compliant JEREMIAH VANDYKE-05/18/2023 @ 15:49 02/15/2023 S-(Annual)Fire Alarm COMMUNITY ELECTRIC/PRIMARY SYSTEMS Reviewed Compliant JEREMIAH VANDYKE-05/18/2023 @ 16:07 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. Printed on 05/18/2023 @ 16:08 Page 3 of 4 GENERAL NOTES JEREMIAH VANDYKE-05/18/2023 @ 16:07 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-05/18/2023 @ 16:08 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-05/18/2023 @ 16:08 Inspection Fee=$100.00 REINSPECTION DATE 06/17/2023 CONTACT SIGNATURE Paula Gourley Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Vn) Signed on:05/18/2023 @ 16:07 QUESTIONS ASOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 05/18/2023 @ 16:08 Page 4 of 4