COMMERCIAL INSPECTION - 1515 E SAN MARNAN DR- 4-5-23 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
12579 05/08/2023 06/10/2023 2023-00011267 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
0\
WATERLOO FIRE RESCUE ;
1. \
INSPECTION REPORT �
/IMMYJOHNS,1515 E SAN MARNAN DR,BLDG 1515 E SAN MARNAN DR,WATERLOO/A 50702
DETAILS
Inspection Date:04/05/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:9995 i Shift: N/A Station: N/A I
Unit: N/A j Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters.Numbers shall not be spelled out. Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm).
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate emergency response.Where access is by
means of a private road and the building cannot be viewed from the public way,a
monument,pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
Inspector:JEFF SIEBEL-Comments:replace faded address with 4"letters of
contrasting color to the background.
FAIL 5307.3.2-Gas detection Where ventilation is not provided in accordance with Section 5307.3.1,a gas
system. detection system shall be provided in rooms or indoor areas and in below-grade
outdoor locations with insulated carbon dioxide systems.Carbon dioxide sensors
shall be provided within 12 inches(305 mm)of the floor in the area where the gas is
expected to accumulate or other approved locations.The system shall be designed
as follows: 1.Activates an audible and visible supervisory alarm at a normally
attended location upon detection of a carbon dioxide concentration of 5,000 ppm
(9000 mg/m3).2.Activates an audible and visible alarm within the room or immediate
area where the system is installed upon detection of a carbon dioxide concentration
of 30,000 ppm(54 000 mg/m3).
Inspector:JEFF SIEBEL-Comments:provide current maintenance as required by
manufactures recommendations.
Printed on 04/06/2023 @ 11:53
Page 1 of 2
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned,properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers.
REINSPECTION DATE
04/26/2023
CONTACT SIGNATURE
Kiley Kruger
Signed on:04/06/2023 @ 11:52 F
g
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/06/2023 @ 11:52
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 04/06/2023 @ 11:53
Page 2 of 2