COMMERCIAL INSPECTION-2830 UNIVERSITY AVE- 1-18-23 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price,
REINSPECTION 1 $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
20526 05/08/2023 06/10/2023 2023-00011266 $100.00
Less Prepayment $0.00
Total Due— $100.00
City of Waterloo
q.'&14 C ,
orky
WATERLOO FIRE RESCUE v - C, ;rh
INSPECTION REPORT
BLDG 2830 UNIVERSITYAVE,2830 UNIVERSITYAVE,WATERLOO/A S0701A\N\C
DETAILS
Inspection Date:01/18/2023 ! Inspection Type:Annual Inspection(1Yr) I Inspection Number:9360 Shift: N/A I Station: N/A i
Unit: N/A I Lead Inspector:JEREMIAH VANDYKE j Other Inspectors:BROCK WELIVER ; Fee:$100.00
STATUS CODE DESCRIPTION
FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Inspector:JEREMIAH VANDYKE-Comments:CONTACT FIRE SPRINKLER COMPANY TO
CORRECT.1.System has past Deficiency Found:Answer:OS&Y control valve leaks and
unable to adjust packing.Needs replaced. Needs to be inspected by licensed
sprinkler contractor and inspection report uploaded into Compliance Engine by
servicing contractor.
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
-44 restored or replaced where damaged,altered,breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-rated assemblies shall be protected by
`' self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:JEREMIAH VANDYKE-Comments:Located in Furnace/mechanical room.
Fire resistance sheet rock is to be REPLACED on ceiling.
•
GENERAL NOTES
Printed on 01/18/2023 @ 14:42
Page 1 of 2
JEREMIAH VANDYKE-12/19/2022 @ 16:52 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-12/19/2022 @ 16:52 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-01/18/2023 @ 14:36 Re inspection fee:$100.00
REINSPECTION DATE
02/17/2023
CONTACT SIGNATURE
Travis Marsh-Napa manager Contact Refused
Refusal Reason:N/A emailed.
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:01/18/2023 @ 14:41 V1 �,✓
QUESTIONS AMOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 01/18/2023 @ 14:42