Loading...
HomeMy WebLinkAbout3910 UNIVERSITY AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE itPi�ter.,, 05/08/2023 06/10/2023 2023-00011268 $80.00 OFalte c?terloo Customer#: 21006 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WALGREENS DRUG STORE#3590 715 Mulberry St 3910 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3910 UNIVERSITY AVE- 5-5-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21006 05/08/2023 06/10/2023 2023-00011268 $80.00 Less Prepayment $0.00 Total Due — $80.00 City of Waterloo n �p'(ERlpO WATERLOO FIRE RESCUE 024 INSPECTION REPORT WALGREENS,3910 UNIVERSITY AVE,BLDG 3910 UNIVERSITY AVE,WATERLOO IA 50701 DETAILS Inspection Date:05/05/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8283 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:repair exit door.must unlatch and swing to full open with less than 15#force. Location:West exit door by fire sprinklers FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments: Repair egress lights. Location:A. By front door above fire extinguishers B.Above patient health room C. Above main stockroom door on stockroom side. Printed an 05/05/2023 @ 15:27 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile Location: Fire Alarm Control Panel Room GENERAL NOTES JEFF SIEBEL-05/05/2023 @ 15:20 annual fire inspection$80 JEFF SIEBEL-05/05/2023 @ 15:20 Fire Sprinkler and Alarm ok until 2/24 REINSPECTION DATE 05/25/2023 CONTACT SIGNATURE Thane Soderstrom Signed on:05/05/2023 @ 15:21 ( CC- • INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/05/2023 @ 15:22 Printed on 05/05/2023 @ 15:27 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/05/2023 @ 15:27 Page 3of3