COMMERCIAL INSPECTION - 3910 UNIVERSITY AVE- 5-5-23 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price j
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
21006 05/08/2023 06/10/2023 2023-00011268 $80.00
Less Prepayment $0.00
Total Due — $80.00
City of Waterloo
n �p'(ERlpO
WATERLOO FIRE RESCUE 024
INSPECTION REPORT
WALGREENS,3910 UNIVERSITY AVE,BLDG 3910 UNIVERSITY AVE,WATERLOO IA 50701
DETAILS
Inspection Date:05/05/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8283 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire
force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force
open doors. required to retract latch bolts or disengage other devices that hold the door in a
closed position.For other swinging doors,as well as sliding and folding doors,the
door latch shall release when subjected to a 15-pound(67 N)force.The door shall be
set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a
full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch
doors shall comply with the following: 1.Where door hardware operates by push or
pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).
2.Where door hardware operates by rotation,the operational force to unlatch the
door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall
comply with the following: 1.For interior swinging egress doors that are manually
operated,other than doors required to be fire rated,the force for pushing or pulling
open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding
doors or folding doors,and doors required to be fire rated,the door shall require
not more than a 30-pound(133 N)force to be set in motion and shall move to a full-
open position when subjected to not more than a 15-pound(67 N)force.
Inspector:JEFF SIEBEL-Comments:repair exit door.must unlatch and swing to full
open with less than 15#force.
Location:West exit door by fire sprinklers
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments: Repair egress lights.
Location:A. By front door above fire extinguishers B.Above patient health room C.
Above main stockroom door on stockroom side.
Printed an 05/05/2023 @ 15:27
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.Joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile
Location: Fire Alarm Control Panel Room
GENERAL NOTES
JEFF SIEBEL-05/05/2023 @ 15:20 annual fire inspection$80
JEFF SIEBEL-05/05/2023 @ 15:20 Fire Sprinkler and Alarm ok until 2/24
REINSPECTION DATE
05/25/2023
CONTACT SIGNATURE
Thane Soderstrom
Signed on:05/05/2023 @ 15:21 ( CC-
•
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:05/05/2023 @ 15:22
Printed on 05/05/2023 @ 15:27
Page 2 of 3