Loading...
HomeMy WebLinkAbout205 W 4TH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,li►.4If,1,;: 05/08/2023 06/10/2023 2023-00011273 $610.00 NNUCustomer#: 24080 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BEST WESTERN 715 Mulberry St 205 W 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-205 W 4TH ST- 5-2-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24080 05/08/2023 06/10/2023 2023-00011273 $610.00 Less Prepayment $0.00 Total Due-* $610.00 City of Waterloo „:\e �pTER(�O WATERLOO FIRE RESCUE ; INSPECTION REPORT BEST WESTERN,205 W 4TH ST,BLD6 205 W 4TH ST,WATERLOO IA 50702 4401 DETAILS Inspection Date:05/02/2023 Inspection Type:Annual Inspection(1 Yr) I Insp ction Number:8564 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A ! Fee:$ .00 STATUS CODE DESCRIPTION \ - FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:Repair broken hardware. Location:door to skywalk from hotel FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Inspector:JEFF SIEBEL-Comments:Provide current annual fire sprinkler inspection report with all discrepancies corrected. Report of 8/3/22 from black hawk sprinkler lists discrepancies including fire sprinkler heads to close together in 1008.Contractor ' must upload online to the compliance engine. • Location: Not Provided Printed on 05/04/2023 @ 10:14 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEFF SIEBEL-Comments:Provide documentation of dryer vent cleaning to the outside of the building with signature and date. Report may be mailed to fire inspector. Location:Commercial house clothes dryers and guest clothes dryers FAIL 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide annual fire door drop test for all floors. Report may be emailed to fire inspector. Location:elevator lobbies FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEFF SIEBEL-Comments:Provide current annual fire alarm fire inspection report with all discrepancies corrected.Currently 140 days past due.Contractor must upload online to the compliance engine. Location: Not Provided GENERAL NOTES JEFF SIEBEL-05/04/2023 @ 10:03 annual inspection$600 JEFF SIEBEL-05/04/2023 @ 10:05 portable heater removed from sales office during inspection. REINSPECTION DATE 05/24/2023 Printed on 05/04/2023 @ 10:14 Page 2of3 CONTACT SIGNATURE Don Schlinger c Gr / Signed on:05/04/2023 @ 10:14 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/04/2023 @ 10:05 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/04/2023 @ 10:14 Page 3 of 3