Loading...
HomeMy WebLinkAbout1600 OLYMPIC DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE /44 1�i �.�;,; 05/02/2023 06/05/2023 2023-00011251 $100.00 �rfi ao. . I � 4 erloa Customer#: 3311 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SUNNYSIDE COUNTRY CLUB 715 Mulberry St 1600 OLYMPIC DR WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1600 OLYMPIC DR-4-11-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price] REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3311 05/02/2023 06/05/2023 2023-00011251 $100.00 Less Prepayment $0.00 Total Due —> $100.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT t 1,11p1' SUNNYSIDE COUNTRY CLUB,1600 OLYMPIC DR,BLDG 1600 OLYMPIC DR,WATERLOO IA S0701 \1 DETAILS Inspection Date:04/11/2023 ( Inspection Type:Annual Inspection(1Yr) I Inspection Number:7874 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide documentation of testing and repair of all egress and exit lights with all discrepancies corrected with signature and date including:A.exit light above FX by stairs in hall from office to bar. B.egress lights dining by office.C.egress light by elevator upper level D.egress light by elevator lower level E.egress light 4'florescent golf simulator room by outside door. F.Exit light bottom of stairs from kitchen.G. Exit light from employee break room to lower kitchen. H. Exit/egress light main door. FAIL 5003.5-Hazard identification Unless otherwise exempted by the fire code official,visible hazard identification signs signs. as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored,dispensed,used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. Inspector:JEFF SIEBEL-Comments:Update NFPA 704 Placards for cold storage building for items actually stored in the building. Hazzard ratings must match SDS sheets. FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:secure all compressed gas cylinders to wall with chain in lower kitchen on both sides of ice machine. Printed on 04/12/2023 @ 09:43 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are 41 required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions(furniture)from obstructing electrical panel by office. FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a usePower supply. permanently installed receptacle.Exceptions: 1.Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Inspector:JEFF SIEBEL-Comments:Each power tap under desk in main office must plug directly into wall outlet,not into another power tap. FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Inspector:JEFF SIEBEL-Comments:install UL listed cord protectors on power cords to desk from wall across walk way in pro shop 4 Printed on 04/12/2023 @ 09:43 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile at bottom of stairs from kitchen. GENERAL NOTES JEFF SIEBEL-04/12/2023 @ 09:41 annual inspection$100 JEFF SIEBEL-04/12/2023 @ 09:14 /Fire Sprinkler Inspection Due 4/18/23 REINSPECTION DATE 05/02/2023 CONTACT SIGNATURE Seth Henricks Signed on:04/12/2023 @ 09:33 (, G/C ) /1. 7 INSPECTOR SIGNATURE JEFF SIEBEL t Signed on:04/12/2023 @ 09:41 Printed on 04/12/2023 @ 09:43 Page 3 of 4 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 • Printed on 04/12/2023 @ 09:43 Page 4 of 4