COMMERCIAL INSPECTION- 1519 E SAN MARNAN DR-4-5-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price]
INSPECTION 1 $40.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES >.,.
10904 05/02/2023 06/05/2023 2023-00011226 $50.00
Less Prepayment $0.00
Total Due -p $50.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT t
ADVANCE AMERICA*5262,1519 E SAN MARNAN DR,BLDG 1519 E SAN MARNAN DR,
WATERLOO/A 50702
DETAILS
Inspection Date:04/05/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:9993 I Shift: N/A 1 Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a
usePower supply. permanently installed receptacle.Exceptions: 1.Where approved for use in a Group A
occupancy or in a meeting room in a Group B occupancy,not more than five
relocatable power taps shall be permitted to be connected together or connected to
an extension cord for temporary use to supply power to electronic equipment.2.
Current taps and relocatable power taps shall not be required to connect directly to
a permanently installed receptacle outlet where used for 90 days or less for the
purpose of testing the performance of such devices.
Inspector:JEFF SIEBEL-Comments:refrigerator and microwave in back room must
each plug directly into a permanent wall outlet
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned, properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers
GENERAL NOTES
JEFF SIEBEL-04/06/2023 @ 11:41 annual inspection$50
Printed on 04/06/2023 @ 11:44
Page 1 of 2
'N
REINSPECTION DATE
04/26/2023
CONTACT SIGNATURE
Carisa Driscoll W-C'
,fSigned on:04/06/2023 @ 11:43 �/
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/06/2023 @ 11:43
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 04/06/2023 @ 11:44
Page 2 of 2