Loading...
HomeMy WebLinkAbout316 MC COY RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE l i Fri r� 05/02/2023 06/05/2023 2023-00011229 $100.00 erloo \so Customer#: 24072 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ELK RUN PRESCHOOL 715 Mulberry St 316 MC COY RD WATERLOO, IA 50703 WATERLOO,IA 50707 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-316 MC COY RD-2-17-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES .. 24072 05/02/2023 06/05/2023 2023-00011229 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo ld\611v WATERLOO FIRE RESCUE (a 0 INSPECTION REPORT ELK RUN PRESCHOOL,316 MC COYRD,BLD6 316 MC COYRD,ELK RUN HEIGHTS U150707 DETAILS Inspection Date:02/17/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:9683 I Shift: N/A I Station: N/A Unit:324-Fire Marshal I Lead Inspector:BROCK WELIVER I Other Inspectors:JEREMIAH VANDYKE I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 403.4.1 -First emergency The first emergency evacuation drill of each school year shall be conducted within 10 evacuation drill. days of the beginning of classes. Inspector:BROCK WELIVER-Comments:Monthly fire drill log should be maintained and kept on the premises. FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:BROCK WELIVER-Comments: Daisy chained power taps were found during the inspection and unplugged during the inspection. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:BROCK WELIVER-Comments:Missing ceiling tiles need to be put back in place Printed on 02/17/2023 @ 12:02 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:BROCK WELIVER-Comments: Doors in the main hallway were propped open using foot wedges and door stops.This building is not equipped with a fire alarm or fire sprinkler system.These doors serve as a primary fire protection feature of the building.These doors either need to be kept closed or electronic hold open devices should be installed. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. alarms. Inspector:BROCK WELIVER-Comments:Smoke alarms need to be tested and maintained.Some devices appear to be dated-follow manufacturers recommendations for replacement-most need to be replaced every 10 years. FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:BROCK WELIVER-Comments: Manual fire alarm/pull station alarm only. Annual testing is required. GENERAL NOTES BROCK WELIVER-02/17/2023 @ 11:30 Fire Sprinkler:N/A BROCK WELIVER-02/17/2023 @ 11:32 Fire Alarm:manual pull station only-annual maintenance records not available for inspection.Annual inspection/service/maintenance should be performed if this has not been conducted already. BROCK WELIVER-02/17/2023 @ 11:34 Smoke Alarms:single station smoke alarms were present in many of the class rooms, some of these appear to be older devices. Manufacturers'recommendations should be followed in the replacement of these devices-many such devices recommend being replaced every 10 years BROCK WELIVER-02/17/2023 @ 11:36 Stage Curtains:documentation for fire retardant application is needed or sample of the material needs to be sent out for flame retardant verification. BROCK WELIVER-02/17/2023 @ 11:37 Dryer Vents:sticker log kept by vent-last cleaned by Harris Cleaning 3/15/2022.Annual cleaning is approaching BROCK WELIVER-02/17/2023 @ 11:38 Kitchen hood cleaning&suppression system:N/A Printed on 02/17/2023 @ 12:02 Page 2of3 T• e GENERAL NOTES BROCK WELIVER-02/17/2023 @ 11:38 Fire Extinguisher:current,serviced by Superior Fire Protection June 2022 BROCK WELIVER-02/17/2023 @ 11:44 This inspection was conducted on behalf of the Waterloo School District for the City of Elk Run Heights and The Boys&Girls Club.Waterloo Fire Rescue is not the Authority Having Jurisdiction(AHJ).Re-inspections of the items listed in this report should be directed to the Waterloo Community School District and the City of Elk Run Heights and its inspectors for compliance. BROCK WELIVER-02/17/2023 @ 11:45 Invoice Contact/Zack Kelly-Waterloo Community Schools/319-404-8085 BROCK WELIVER-02/17/2023 @ 12:01 Inspection Fee=$100 NEXT INSPECTION RATE 02/17/2024 CONTACT SIGNATURE Steve Santomauro-City Inspector Elk Contact Refused Run Heights Refusal Reason:N/A INSPECTOR SIGNATURE BROCK WELIVER Signed on:02/17/2023 @ 12:02 QUESTIONS ABOUT YOUR INSPECTION? BROCK WELIVER brock.weliver@waterloo-ia.org 3192914460 Printed on 02/17/2023 @ 12:02 Page 3 of 3