Loading...
HomeMy WebLinkAbout1509 FLAMMANG DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE 05/02/2023 06/05/2023 2023-00011231 $50.00 Ier!°o Customer#: 24069 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SMOKE O'S VAPOR 715 Mulberry St 1509 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1509 FLAMMANG DR-3-27-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price] INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE ` + DUE DATE :, INVOICE# CHARGES 24069 05/02/2023 06/05/2023 2023-00011231 $50.00 Less Prepayment $0.00 Total Due—> $50.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT O SMOKE O S VAPOR,1509 FLAMMAN6 DR,BLDG 1509 FLAMMANG DR,WATERLOO LA 50702 DETAILS Inspection nspection Type:Annual Inspection(1Yr) I Inspection Number:9955 I Shift: N/A I Station: N/A I Unit: N/A I ad Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit-egress light back door. FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters.Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments:Install permanent address on street side of building.Letters must be 4"tall and be of a contrasting color to the background. FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Printed on 04/03/2023 @ 09:43 Page 1 of 4 STATUS CODE DESCRIPTION Inspector:JEFF SIEBEL-Comments:Remove all extension cords and electrical cords from ceiling. Nt� FAIL 603.E Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable • appliances.Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove extension cords and power strips daisy rs ,, chained to display cases etc. Extension cords and power strips are not a substitute ' 3 #r for permanent power.Install permanent outlets with proper permits and inspections. FAIL 704.1 Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in back room. Printed on 04/03/2023 @ 09:43 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations:1.In new and existing Group A,B,E,F,H,I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1;1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector:JEFF SIEBEL-Comments:Install a currently serviced 2A-10bC fire extinguisher in front area of store in an accessible location 4"to 5'above the floor. If purchased mount receipt on bottom of extinguisher to confirm service date. GENERAL N ES JEFF SIE:EL-04/03/2023 @ 09: : annual ins ction$50 JEFF SIEBEL-04/03/2023 @ 09:36 REINSPECTION DATE 04/24/2023 Printed on 04/03/2023 @ 09.43 Page 3 of 4 CONTACT SIGNATURE Belel Mrushed Signed on:04/03/2023 @ 09:17 etL7 I h el r INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/03/2023 @ 09:17 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/03/2023 @ 09:43 Page 4 of 4