Loading...
HomeMy WebLinkAbout3964 W AIRLINE HWY INVOICE DATE DUE DATE . INVOICE# TOTAL DUE / '�a'► ; 05/02/2023 06/05/2023 2023-00011232 $80.00 (;?terloo �o Customer#: 24068 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable NAJO TRUCKING 715 Mulberry St 3964 W AIRLINE HWY WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3964 W AIRLINE HWY-3-8-23 FOR BILLING INQUIRY: (319)291-4323 Description I ' Total Price] INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24068 05/02/2023 06/05/2023 2023-00011232 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo WATERLOO FIRE RESCUE ( •°\ INSPECTION REPORT �0 NAJO TRUCKING,3964 WAIRUNE HWY,BLD6 3964 WAIRLINE HWY,WATERLOO IA 50703 DETAILS Inspection Date:03/08/2023 j Inspection Type:Annual Inspection(1Yr) I Inspection Number:9783 I Shift: N/A ( Station: N/A Unit: N/A I Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An 1 .. exit or exit passageway shall not be used for any purpose that interferes with a k means of egress. Inspector:JEREMIAH VANDYKE-Comments:Exit door is to be cleared of pallets and storage tank.The 2x4 wood crossbar is to be removed. t \\% S +,x FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:All Egress emergency lighting are to be repaired or replaced located in shop/garage area. ) Printed on 03/082023 @ 15:57 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm system is to be inspected annually by licensed fire alarm contractor. Inspection report is to be uploaded to Compliance Engine website by servicing contractor.Any deficiencies found by fire alarm contractor are to be corrected as soon as possible. mit FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Inspector:JEREMIAH VANDYKE-Comments:Sprinkler system is to be inspected annually by licensed sprinkler contractor. Inspection report is to be uploaded to Compliance Engine website by servicing contractor.Any deficiencies found by C Sprinkler contractor are to be corrected as soon as possible. 1.7 • FAIL 506.1 -Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector:JEREMIAH VANDYKE-Comments:Commercial Knox box must be ordered and placed in approved location by fire official.CALL fire offical when Knoxbox is received for proper placement. Knox Box can be ordered from Knoxbox.com. Recommended on website is Commercial KnoxBoxes KnoxBox®3200 Standard Capacity Model:3261 For Waterloo Fire Rescue FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEREMIAH VANDYKE-Comments:Master Key is needed for Knoxbox for access to building by fire department. Printed on 03/08/2023 @ 15:57 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments: Durable legible signage needed for sprinkler riser room and fire alarm panel to be placed on door.Stating"Sprinkler Riser&FACP". FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector JEREMIAH VANDYKE-Comments:Open wiring splice needs addressed located on north wall of garage for a light fixture. FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEREMIAH VANDYKE-Comments:Can use extension cord with multi plug outlets with multiple power taps plugged into it.Cannot daisy chain power taps. PIPPIr Located in back office. Printed on 03/08/2023 @ 15:57 Page 3 of 5 STATUS CODE DESCRIPTION FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm system is to be inspected annually by licensed fire alarm contractor.Inspection report is to be uploaded to Compliance Engine website by servicing contractor.Any deficiencies found by fire alarm contractor are to be corrected as soon as possible. GENERAL NOTES JEREMIAH VANDYKE-03/08/2023 @ 15:57 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-03/08/2023 @ 15:57 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-03/08/2023 @ 15:57 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-03/08/2023 @ 15:57 Inspection Fee=$80.00 JEREMIAH VANDYKE-03/08/2023 @ 15:02 Fire Extinguishers serviced/compliant by Proshield in November 2022. JEREMIAH VANDYKE-03/08/2023 @ 15:56 Extension cords were removed from under garage door during inspection. REINSPECTION DATE 04/07/2023 Printed on 03/08/2023 @ 15:57 Page 4of5 CONTACT SIGNATURE Rusmir Okanovic Contact Refused Refusal Reason:N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE (� Signed on:03/08/2023 @ 15:52 �' L QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 03/08/2023 @ 15:57 Page 5of5