Loading...
HomeMy WebLinkAbout1503 E SAN MARNAN DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE 6 7 1Fshr ram; 05/02/2023 06/05/2023 2023-00011233 $80.00 er100 ‘° Customer#: 24067 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GREEN LEAF TOBACCO AND E-CIGS 715 Mulberry St 1503 E SAN MARNAN DR SUITE C WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1503 E SAN MARNAN DR-4-27-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price] INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE. INVOICE# CHARGES. 24067 05/02/2023 06/05/2023 2023-00011233 $80.00 Less Prepayment $0.00 Total Due-+ $80.00 City of Waterloo �O WATERLOO FIRE RESCUE INSPECTION REPORT 1 GREEN LEAF TOBACCO AND E-CIGS,1503 E SAN HARNAN SUITE CDR,WIG 1503 E SAN MARNAN DR,WATERLOO/A 50702 41,410116 DETAILS Inspection Date:04/27/2023 ( Inspection Type:Annual Inspection(1Yr) I Inspection Number:930 I Shift: N/A ( Station: N/A I Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A ; Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:Remove shelving and obstructions to rear exit door or remove exit sign and properly contain wires.Occupant load 41 so second exit not required..(3120 square feet-669 2451 divided by 60.) Location:rear exit in back storage room FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector JEFF SIEBEL-Comments:remove obstruction(E-Z Wider Balloon)from exit light Location: Near front of store. I '7 Printed on 05/02/2023 @ 09:01 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be 1r providedin front of electrical service equipment.Where the electrical service --- ' equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located _ within the designated working space.Exceptions: 1.Where other dimensions are V 3 required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm), Inspector JEFF SIEBEL-Comments:remove obstructions to electric panel.maintain a • minimum of 36"clearance at all times. Location:back of store FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:remove combustible storage from above the ceiling and replace missing ceiling tile. Location:back room Printed on 05/02/2023 @ 09:01 Page 2 of 4 • STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual inspection for fire extinguishers Location: Front entrance FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:remove obstructions(vending machine)from in front of fire extinguisher or relocate fire extinguisher.Maintain a minimum of 36" e u clearance to fire extinguisher at all times. Location:front by vending machine -ti p GENERAL NOTES JEFF SIEBEL-05/02/2023 @ 08:56 annual inspection$80 REINSPECTION DATE 05/18/2023 Printed on 05/02/2023 @ 09:01 Page 3 of 4 CONTACT SIGNATURE Mo dSigned on:05/02/2023 @ 08:59 �r.� G/ v� INSPECTOR SIGNATURE F SIEBEL /(////3 Signed d on:05/02/2023 @ 08:59 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/02/2023 @ 09:01 Page 4 of 4