Loading...
HomeMy WebLinkAbout2424 RANCHERO RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE �,�� ��,► -9r._'•� 05/02/2023 06/05/2023 2023-00011239 $80.00 Wire0 rloo Ao Customer#: 15371 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CASEY'S GENERAL STORE#2867 715 Mulberry St 2424 RANCHERO RD WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2424 RANCHERO RD -4-28-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 15371 05/02/2023 06/05/2023 2023-00011239 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo 67-3 WATERLOO FIRE RESCUE �PtER�DO INSPECTION REPORT `h CASEY`S GENERAL STORE#2867,2424 RANCHERO RD,BLDG 2867 RANCHERO RD, WATERLOO d IA S0701 DETAILS Inspection Date:04/28/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8051 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair exit/egress light above front door. Location:above front door FAIL 5003.5-Hazard identification Unless otherwise exempted by the fire code official,visible hazard identification signs signs. as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored,dispensed,used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. Inspector:JEFF SIEBEL-Comments: Install proper NFPA 704 Placards on all 4 sides of both propane tanks. Location: Not Provided FAIL 5003.5-Hazard identification Unless otherwise exempted by the fire code official,visible hazard identification signs signs. as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored,dispensed,used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. Inspector:JEFF SIEBEL-Comments: Install proper NFPA 704 Placards on all 4 sides of both propane tanks. Location: Not Provided Printed on 05/01/2023 @ 11:09 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 5003.5.1 -Markings. Individual containers,cartons or packages shall be conspicuously marked or labeled in an approved manner. Rooms or cabinets containing compressed gases shall be conspicuously labeled:"COMPRESSED GAS." Inspector:JEFF SIEBEL-Comments: Install permanent label stating"Propane"on both sides of propane tanks. Location: Not Provided FAIL 5003.7.1 -Smoking. Smoking shall be prohibited and"No Smoking"signs provided as follows: 1.In rooms or areas where hazardous materials are stored or dispensed or used in open systems in amounts requiring a permit in accordance with Section 5001.5.2.Within 25 feet(7620 mm)of outdoor storage,dispensing or open use areas.3.Facilities or areas within facilities that have been designated as totally"no smoking"shall have"No Smoking"signs placed at all entrances to the facility or area. Designated areas within such facilities where smoking is permitted either permanently or temporarily,shall be identified with signs designating that smoking is permitted in these areas only.4.In rooms or areas where flammable or combustible hazardous materials are stored, dispensed or used.Signs required by this section shall be in English as a primary language or in symbols allowed by this code and shall comply with Section 310. Inspector:JEFF SIEBEL-Comments: Install"No Smoking"signs on both sides of the propane tanks. Location: Not Provided FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:replace missing moisture proof light covers in walk in cooler. Location: Not Provided FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:replace missing moisture proof light covers in walk in cooler. - Location: Not Provided r- - �( Printed on 05/01/2023 @ 11:09 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:remove obstructions to k-guard fire extinguisher in kitchen Location: kitchen FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:remove obstructions to k-guard fire extinguisher in kitchen Location:kitchen a •AN ‘ ' 1\‘1111i GENERAL NOTES JEFF SIEBEL-05/01/2023 @ 10:39 annual inspection$80 REINSPECTION DATE 05/22/2023 CONTACT SIGNATURE Christine Crane 2023 Signed on:05/01/2023 @ 10:15 i� L' f I 5 INSPECTOR SIGNATURE JEFF SIEBEL ),,,, , Signed on:05/01/2023 @ 10:15 Printed on 05/01/2023 @ 11:09 Page 3 of 4 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL ieff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/01/2023 @ 11:09 Page 4 of 4