COMMERCIAL INSPECTION- 1825 E SAN MARNAN DR-4-19-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
15159 05/02/2023 06/05/2023 2023-00011254 $80.00
Less Prepayment $0.00
Total Due —� $80.00
City of Waterloo
WATERLOO FIRE RESCUE 44 o
INSPECTION REPORT to,
CVS PHARMACY,1825 E SAN MARNAN DR,BLDG 1825 E SAN MARNAN DR,WATERLOO IA
50702
DETAILS
Inspection Date:04/19/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number: 10092 Shift: N/A I Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ! Other Inspectors: N/A Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair outside egress light by outside dock door.
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:Repair exit/egress lights:A. by side door by fake
nails.B.in pharmacy.
FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system
equipment to permit immediate safe operation and maintenance of such equipment.
Storage,trash and other materials or objects shall not be placed or kept in such a
manner that would prevent such equipment from being readily accessible.
""�-- Inspector:JEFF SIEBEL-Comments:remove obstructions to fire sprinkler riser.(ramp)
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact. Extension cords shall be used only with portable
appliances.Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:Remove extension cords install permanent power
with permits and inspections:A.Photo copier B.behind check out counter to fan
Printed on 04/21/2023 @ 11:56
Page 1 of 2
STATUS CODE DESCRIPTION
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in front entry.
GENERAL NOTES
JEFF SIEBEL-04/21/2023 @ 11:49 annual inspection$80