Loading...
HomeMy WebLinkAbout1825 E SAN MARNAN DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE fir+��a a. -4 05/02/2023 06/05/2023 2023-00011254 $80.00 °terioo Customer#: 15159 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CVS PHARMACY 715 Mulberry St ATTN: CATHY TARDIE WATERLOO, IA 50703 ONE CVS DRIVE, MC#1160 WOONSOCKET, RI 02895 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1825 E SAN MARNAN DR-4-19-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 15159 05/02/2023 06/05/2023 2023-00011254 $80.00 Less Prepayment $0.00 Total Due —� $80.00 City of Waterloo WATERLOO FIRE RESCUE 44 o INSPECTION REPORT to, CVS PHARMACY,1825 E SAN MARNAN DR,BLDG 1825 E SAN MARNAN DR,WATERLOO IA 50702 DETAILS Inspection Date:04/19/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number: 10092 Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL ! Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair outside egress light by outside dock door. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair exit/egress lights:A. by side door by fake nails.B.in pharmacy. FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage,trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. ""�-- Inspector:JEFF SIEBEL-Comments:remove obstructions to fire sprinkler riser.(ramp) FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:Remove extension cords install permanent power with permits and inspections:A.Photo copier B.behind check out counter to fan Printed on 04/21/2023 @ 11:56 Page 1 of 2 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in front entry. GENERAL NOTES JEFF SIEBEL-04/21/2023 @ 11:49 annual inspection$80 REINSPECTION DATE 05/10/2023 CONTACT SIGNATURE Kyle schulz A- C J 4 Signed on:04/21/2023 @ 11:54 C� INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/21/2023 @ 11:54 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/21/2023 @ 11:56 Page 2of2