COMMERCIAL INSPECTION- 321 W 4TH ST-3-7-23
FOR BILLING INQUIRY: (319)291-4323
LDescription
Total Price j
INSPECTION 2,000
OCCUPANCY FEE $70.00
$10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE#
10626 04/27/2023 05/30/2023 2023-00011222 CHARGES
$80.00
Less Prepayment $0.00
Total Due-f $80.00
City of Waterloo
WATERLOO FIRE RESCUE �PjER(0O
�
INSPECTION REPORT
LA PLACIT 321 W 4TH� ST,BLDS 321 W 4TH ST,WATERLOO/A 50702 UP
DETAILS
Inspection Date:03/07/2023 f Inspection Type:Annual Inspection(1Yr) I Inspection Number:7809 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A i Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair/replace egress/exit light by kitchen.
FAIL 5807.2.1 -Securing Containers,cylinders and tanks shall be secured in accordance with Section 5303.5.3.
containers.
Inspector:JEFF SIEBEL-Comments:secure all compressed gas cylinders in pop room.
FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tiles in 2nd storage room
behind counter.
FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every
system service. six months and after activation of the system.Inspection shall be by qualified
individuals,and a certificate of inspection shall be forwarded to the fire code official
upon completion.
Inspector:JEFF SIEBEL-Comments:provide current documentation of kitchen hood
fire suppression inspection report with all discrepancies corrected.Contractor must
upload online to the compliance engine.
Printed on 03/28/2023 @ 11:58
Page 1 of 2
REINSPECTION DATE
03/28/2023
CONTACT SIGNATURE
Manuel Lopez
Signed on:03/08/2023 @ 10:51 )(
cC ��
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:03/08/2023 @ 10:51