Loading...
HomeMy WebLinkAbout321 W 4TH ST . INVOICE DATE DUE DATE INVOICE# TOTAL DUE ��//A k &Va�� �I = 04/27/2023 lle 05/30/2023 2023-00011222 $80.00 Customer#: 10626 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LA PLACITA MEXICAN STORE 715 Mulberry St 321 W 4TH ST WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 321 W 4TH ST-3-7-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# 10626 04/27/2023 05/30/2023 2023-00011222 CHARGES $80.00 Less Prepayment $0.00 Total Due-f $80.00 City of Waterloo WATERLOO FIRE RESCUE �PjER(0O � INSPECTION REPORT LA PLACIT 321 W 4TH� ST,BLDS 321 W 4TH ST,WATERLOO/A 50702 UP DETAILS Inspection Date:03/07/2023 f Inspection Type:Annual Inspection(1Yr) I Inspection Number:7809 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A i Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair/replace egress/exit light by kitchen. FAIL 5807.2.1 -Securing Containers,cylinders and tanks shall be secured in accordance with Section 5303.5.3. containers. Inspector:JEFF SIEBEL-Comments:secure all compressed gas cylinders in pop room. FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tiles in 2nd storage room behind counter. FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system.Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:provide current documentation of kitchen hood fire suppression inspection report with all discrepancies corrected.Contractor must upload online to the compliance engine. Printed on 03/28/2023 @ 11:58 Page 1 of 2 REINSPECTION DATE 03/28/2023 CONTACT SIGNATURE Manuel Lopez Signed on:03/08/2023 @ 10:51 )( cC �� INSPECTOR SIGNATURE JEFF SIEBEL Signed on:03/08/2023 @ 10:51 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/28/2023 @ 11:58 Page 2 of 2