Loading...
HomeMy WebLinkAbout1503 E SAN MARNAN DR (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE l�dil \ �'1�i\�I��= 04/27/2023 05/30/2023 5/30/2023 2023-00011211 $50.00 �fertoo �o Customer#: 22949 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BOOST MOBILE 715 Mulberry St 1503 E SAN MARNAN DR WATERLOO, IA 50703 SUITE B WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1503 E SAN MARNAN DR- 3-31-23 FOR BILLING INQUIRY: (319)291-4323 J L Description Total Price e] INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22949 04/27/2023 05/30/2023 2023-00011211 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo qqcf WATERLOO FIRE RESCUE �pSERt00 INSPECTION REPORT '` It4 BOOST MOBILE,1503 E SAN MARNAN D BLDG 1503 E SAN MARNAN D� R.WATERLOO IA 50702 DETAILS Inspection Date:03/31/2023 Inspection Type:Annual Inspection(1Yr) ! Inspection Number:931 I Shift: N/A Station: N/A I Unit: N/A I Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A Fee:$50.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress light by front door. FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 . volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be 2wQb providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located *..- - __ within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas .._,,,,ip ' that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:Remove obstructions from in front of the electrical panel. maintain a minimum of 36"clearance at all times. FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:refrigerator in office must plug directly into wall . , outlet.Any appliance that contains a motor,produces heat or cooling must plug aj )114, ,- directly into wall outlet. `t OW 4 Printed on 04/04/2023 @ 09:28 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:Remove power cords and extension cords above ceiling:A.front of store B.office Ytf FAIL 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any combustible materials.Portable,electric space heaters shall be operated only in locations for which they are listed. Inspector:JEFF SIEBEL-Comments:remove heater from behind counter,not rated for commercial list. FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. GENERAL NOTES Printed on 04/04/2023 @ 09:28 Page 2 of 3 JEFF SIEBEL-04/04/2023 @ 09:28 annual inspection$50 REINSPECTION DATE 04/21/2023 CONTACT SIGNATURE Edis .L` Signed on:04/04/2023 @ 09:26 / ° INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/04/2023 @ 09:26 ice"/ QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/04/2023 @ 09:28 Page 3 of 3