Loading...
HomeMy WebLinkAbout1415 E SAN MARNAN . INVOICE DATE DUE DATE INVOICE# TOTAL DUE /Ii 1Paii► , - 04/27/2023 05/30/2023 2023-0001121 0 �/ $80.00 �r�'rloo \o Customer#: 22675 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable AMIGOS 715 Mulberry St 1415 E SAN MARNAN DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1415 E SAN MARNAN -2-14-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price ] INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22675 04/27/2023 05/30/2023 2023-00011210 $80.00 Less Prepayment $0.00 Total Due-> $80.00 City of Waterloo WATERLOO FIRE RESCUE \--\'' .407,,, INSPECTION REPORT )), 11 \ ZI°: AMIGOS 2,1415 E SAN MARNAN DR,BLDG 1415 E SAN MARNAN DR,WATERLOO IA 50702 DETAILS Inspection Date:02/14/2023 i Inspection Type:Annual Inspection(1Yr) 1 Inspection Number:7464 1 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Contact Building Official Greg Ahlhelm 319-291- 4319 concerning building permits for gazebo structures in assembly area. ot...._:0,..„‘....:-.41 j. ..„,,1 e...... 0 irm w � �[ll.� NXf a�*�-I 4S ` $ Or 11E ,„,.., ., :' . t � }J T r i firki, ...3.. - ' '-,,, . ....._ ...,...__ _ Printed on 02/16/2023 @ 11:03 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a ,,,, ■ means of egress. Inspector:JEFF SIEBEL-Comments:reduce storage in egress exit path to the south WA".17110104 -- exit.Maintain a minimum of 36"clearance and storage must be stable and secure. _ v FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:Repair egress light in kitchen FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public. Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:secure compressed gas cylinders with chain in kitchen and in back room. Printed on 02/16/2023 @ 11:03 Page 2 of 6 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) 7� in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be ql. . • providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be l - --, - not less than the width of the equipment.Storage of materials shall not be located ' r�x ,, ,, within the designated working space.Exceptions: 1.Where other dimensions are - - . — ` _ i required or allowed by NFPA 70.2.Access openings into attics or under-floor areas i �- that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to elecrical panels. Maintain +,,,,T, a minimum clearance of 9"on each side and 36"in front of electrical panels. - ' '� r , t a. !. �� ~ yL i - -- i ...„..,_.Rint �'a 8 FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Inspector:JEFF SIEBEL-Comments:remove power taps from wall cavities going to Point of sale register.Install permanent power with electrical permit and inspections. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove all extension cords including cord from kitchen to bar plugged into power strip and appliances.Appliances must plug directly into wall outlet. Install permanent power with electrical permit and inspections. Printed on 02/16/2023 @'•1:03 Page 3 of 6 STATUS CODE DESCRIPTION FAIL 606.3.3.1 -Inspection. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Inspector:JEFF SIEBEL-Comments:Replace broken grease filter. NItek FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire suppression inspection report with all discrepancies corrected.Current inspection from proshield indicates deficiency.Contractor must upload corrections online to the compliance engine. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile. Printed on 02/16/2023 @ 11:03 Page 4 of 6 STATUS CODE DESCRIPTION FAIL 904.13.1 -Manual system A manual actuation device shall be located at or near a means of egress from the operation. cooking area not less than 10 feet(3048 mm)and not more than 20 feet(6096 mm) from the kitchen exhaust system.The manual actuation device shall be installed not more than 48 inches(1200 mm)nor less than 42 inches(1067 mm)above the floor and shall clearly identify the hazard protected.The manual actuation shall require a maximum force of 40 pounds(178 N)and a maximum movement of 14 inches(356 mm)to actuate the fire suppression system. Exception:Automatic sprinkler systems shall not be required to be equipped with manual actuation means. Inspector:JEFF SIEBEL-Comments: IMMEDIATLY repair pull station.currently ripped off of wall and will not operate correctly. FAIL 906.4.2-Class K portable fire Where hazard areas include deep fat fryers,listed Class K portable fire extinguishers extinguishers for deep fat shall be provided as follows: 1.For up to four fryers having a maximum cooking fryers. medium capacity of 80 pounds(36.3 kg)each:one Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity.2.For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds(36.3 kg)each:one additional Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity shall be provided.3.For individual fryers exceeding 6 square feet(0.55 m2)in surface area:Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturer's recommendations. Inspector:JEFF SIEBEL-Comments:remove obstructions to k-guard fire extinguisher in kitchen.(remove appliances etc or relocate fire extinguisher).maintain a minimum of 36"clearance.to fire extinguisher. Fire extinguisher should be 4"to 5'above floor in a readily accessible area.K-guard must be between 10 and 20 feet from fryer. REINSPECTION DATE 03/08/2023 CONTACT SIGNATURE Oscar Valdivia 4, Signed on:02/16/2023 @ 10:54 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/16/2023 @ 10:54 Printed on 02/16/2023 @ 11:03 Page 5 of 6 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/16/2023 @ 11:03 Page 6 of 6