COMMERCIAL INSPECTION- 1415 E SAN MARNAN -2-14-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price
]
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
22675 04/27/2023 05/30/2023 2023-00011210 $80.00
Less Prepayment $0.00
Total Due-> $80.00
City of Waterloo
WATERLOO FIRE RESCUE \--\'' .407,,,
INSPECTION REPORT )), 11 \
ZI°:
AMIGOS 2,1415 E SAN MARNAN DR,BLDG 1415 E SAN MARNAN DR,WATERLOO IA 50702
DETAILS
Inspection Date:02/14/2023 i Inspection Type:Annual Inspection(1Yr) 1 Inspection Number:7464 1 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 102.4-Application of building The design and construction of new structures shall comply with the International
code. Building Code,and any alterations,additions,changes in use or changes in
structures required by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Inspector:JEFF SIEBEL-Comments:Contact Building Official Greg Ahlhelm 319-291-
4319 concerning building permits for gazebo structures in assembly area.
ot...._:0,..„‘....:-.41 j. ..„,,1 e...... 0 irm
w � �[ll.� NXf a�*�-I
4S ` $
Or 11E ,„,.., ., :' .
t � }J
T
r
i firki, ...3.. - ' '-,,,
. ....._ ...,...__ _
Printed on 02/16/2023 @ 11:03
Page 1 of 6
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
,,,, ■ means of egress.
Inspector:JEFF SIEBEL-Comments:reduce storage in egress exit path to the south
WA".17110104
-- exit.Maintain a minimum of 36"clearance and storage must be stable and secure.
_ v
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:Repair egress light in kitchen
FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling
compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas
cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing
containers,cylinders and tanks to a fixed object with one or more restraints.
2.Securing containers,cylinders and tanks on a cart or other mobile device designed
for the movement of compressed gas containers,cylinders or tanks.3. Nesting of
compressed gas containers,cylinders and tanks at container filling or servicing
facilities or in sellers'warehouses not open to the public. Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct
the required means of egress.4.Securing of compressed gas containers,cylinders
and tanks to or within a rack,framework,cabinet or similar assembly designed for
such use. Exception:Compressed gas containers,cylinders and tanks in the process
of examination,filling,transport or servicing.
Inspector:JEFF SIEBEL-Comments:secure compressed gas cylinders with chain in
kitchen and in back room.
Printed on 02/16/2023 @ 11:03
Page 2 of 6
STATUS CODE DESCRIPTION
FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided
clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000
volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000
volts.The minimum required working space shall be not less than 30 inches(762 mm)
7� in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be
ql. . • providedin front of electrical service equipment.Where the electrical service
equipment is wider than 30 inches(762 mm),the minimum working space shall be
l - --, - not less than the width of the equipment.Storage of materials shall not be located
' r�x ,, ,, within the designated working space.Exceptions: 1.Where other dimensions are
- - . — `
_ i required or allowed by NFPA 70.2.Access openings into attics or under-floor areas
i �-
that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments:remove obstructions to elecrical panels. Maintain
+,,,,T, a minimum clearance of 9"on each side and 36"in front of electrical panels.
- '
'� r
,
t a.
!. �� ~
yL
i - -- i
...„..,_.Rint
�'a 8
FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under
doors or floor coverings,or be subject to environmental or physical damage.
Inspector:JEFF SIEBEL-Comments:remove power taps from wall cavities going to
Point of sale register.Install permanent power with electrical permit and inspections.
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
appliances. Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:remove all extension cords including cord from
kitchen to bar plugged into power strip and appliances.Appliances must plug directly
into wall outlet. Install permanent power with electrical permit and inspections.
Printed on 02/16/2023 @'•1:03
Page 3 of 6
STATUS CODE DESCRIPTION
FAIL 606.3.3.1 -Inspection. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code
official. Inspections shall be completed by qualified individuals.
Inspector:JEFF SIEBEL-Comments:Replace broken grease filter.
NItek
FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the
inspection,a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the cleaning
and when the cleaning took place.Such records shall be completed after each
inspection or cleaning and maintained.
Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire
suppression inspection report with all discrepancies corrected.Current inspection
from proshield indicates deficiency.Contractor must upload corrections online to the
compliance engine.
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile.
Printed on 02/16/2023 @ 11:03
Page 4 of 6
STATUS CODE DESCRIPTION
FAIL 904.13.1 -Manual system A manual actuation device shall be located at or near a means of egress from the
operation. cooking area not less than 10 feet(3048 mm)and not more than 20 feet(6096 mm)
from the kitchen exhaust system.The manual actuation device shall be installed not
more than 48 inches(1200 mm)nor less than 42 inches(1067 mm)above the floor
and shall clearly identify the hazard protected.The manual actuation shall require a
maximum force of 40 pounds(178 N)and a maximum movement of 14 inches(356
mm)to actuate the fire suppression system. Exception:Automatic sprinkler systems
shall not be required to be equipped with manual actuation means.
Inspector:JEFF SIEBEL-Comments: IMMEDIATLY repair pull station.currently ripped
off of wall and will not operate correctly.
FAIL 906.4.2-Class K portable fire Where hazard areas include deep fat fryers,listed Class K portable fire extinguishers
extinguishers for deep fat shall be provided as follows: 1.For up to four fryers having a maximum cooking
fryers. medium capacity of 80 pounds(36.3 kg)each:one Class K portable fire extinguisher
of a minimum 1.5-gallon(6 L)capacity.2.For every additional group of four fryers
having a maximum cooking medium capacity of 80 pounds(36.3 kg)each:one
additional Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity
shall be provided.3.For individual fryers exceeding 6 square feet(0.55 m2)in surface
area:Class K portable fire extinguishers shall be installed in accordance with the
extinguisher manufacturer's recommendations.
Inspector:JEFF SIEBEL-Comments:remove obstructions to k-guard fire extinguisher
in kitchen.(remove appliances etc or relocate fire extinguisher).maintain a minimum
of 36"clearance.to fire extinguisher. Fire extinguisher should be 4"to 5'above floor
in a readily accessible area.K-guard must be between 10 and 20 feet from fryer.
REINSPECTION DATE
03/08/2023
CONTACT SIGNATURE
Oscar Valdivia 4,
Signed on:02/16/2023 @ 10:54
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:02/16/2023 @ 10:54
Printed on 02/16/2023 @ 11:03