Loading...
HomeMy WebLinkAbout1400 MAXHELEN BLVD INVOICE DATE DUE DATE INVOICE# TOTAL DUE /17aFig P.M 04/27/2023 05/30/2023 2023-00011203 $100.00 Customer#: 22995 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LANDMARK COMMONS 715 Mulberry St 1400 MAXHELEN BLVD WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1400 MAXHELEN BLVD -3-2-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price] REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES _ 22995 04/27/2023 05/30/2023 2023-00011203 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo 9 WATERLOO FIRE RE SCUE INSPECTION REPORT LANDMARK COMMONS,1400 MAXHELEN BLVD,BLDG 1400 MAXHELEN BLVD,WATERLOO IA �„� 5070E `�' DETAILS Inspection Date:03/02/2023 Inspection Type:Annual Inspection(1 Yr) I Inspection Number:7518 ! Shift: N/A ' Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE j Other Inspectors: N/A Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:Starting record log for all EXIT and EGRESS lights for testing and maintenance for entire building. Exit lights tested and failed,located: 1.Near garage entrance.2.Near Communication room.3.Outside of Stair 4.Near room 2203.5.Near room 2303.6.All 3 exits lights located in Pool area.7. 2 exit lights near mail room area.8.Outside of Stair 3 1st floor.9.Outside of stair 4 near room 1221. 10.Near room 1201.11.Outside stair 1 2nd floor. FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments:Need Generator records and load bank testing of inspection and maintenance. FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Inspector:JEREMIAH VANDYKE-Comments:Open deficiencies,contact contractor to correct deficiencies and have report uploaded to compliance engine by servicing contractor. Printed on 03/03/2023 @ 16:13 Page 1 of 5 STATUS CODE DESCRIPTION m�,I 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system i�a equipment to permit immediate safe operation and maintenance of such equipment. Storage,trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. • Inspector:JEREMIAH VANDYKE-Comments:Removing storage around sprinkler riser and putting up sign. nig { FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. - Inspector:JEREMIAH VANDYKE-Comments: Loose wiring on ceiling located on 1st floor"1000"side in Janitor/housekeeping room. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable f appliances.Extension cords marked for indoor use shall not be used outdoors. • • �_�. Inspector:JEREMIAH VANDYKE-Comments:Room 1102,cord pinched in door for lights. Printed on 03/03/2023 @ 16:13 Page 2of5 STATUS CODE DESCRIPTION FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments:Exhaust Duct system must be cleaned from the dryer to the outside documented by who and when serviced,NEED RECORDS.----2021 Code-610.1.2 Maintenance.The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a 4 ="; ' horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the #: intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. .+s Inspector:JEREMIAH VANDYKE-Comments: Missing or broke ceiling tiles located in:1. • .._ Men's pool restroom.2.in kitchen FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEREMIAH VANDYKE-Comments: Doors not closing properly located in: 1. Trash recycling room on"1000"and"2000"side.2.Communication door.3.2nd floor mechanical room by room 1203. FAIL 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Inspector:JEREMIAH VANDYKE-Comments: Rolling fire door located in garage/basement near carpenter's shop needs inspection form. Printed on 03/03/2023 @ 16:13 Page 3 of 5 STATUS CODE DESCRIPTION FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments: Broken horn strobe in basement/garage near stair#6. a= ter , GENERAL NOTES JEREMIAH VANDYKE-03/03/2023 @ 15:24 Fire Extinguishers serviced/compliant by Superior Fire in October 2022. JEREMIAH VANDYKE-03/03/2023 @ 15:56 11/21/2022 S-Kitchen Hood Suppression SUPERIOR FIRE PROTECTION EQUIPMENT Reviewed Compliant JEREMIAH VANDYKE-03/03/2023 @ 15:56 10/19/2022 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-03/03/2023 @ 15:57 07/29/2022 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Deficient JEREMIAH VANDYKE-03/03/2023 @ 15:57 07/29/2022 S-Private Fire Hydrants BLACKHAWK AUTOMATIC SPRINKLERS,INC. Reviewed Compliant JEREMIAH VANDYKE-03/03/2023 @ 15:57 05/25/2022 L-(Annual)Kitchen Exhaust HARRIS CLEANING SERVICE AND AH Reviewed Compliant JEREMIAH VANDYKE-03/03/2023 @ 15:58 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. Printed on 03/03/2023 @ 16:13 Page 4 of 5 GENERAL NOTES JEREMIAH VANDYKE-03/03/2023 @ 15:58 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-03/03/2023 @ 16:12 Inspection Fee=$100.00 REINSPECTION DATE 04/02/2023 CONTACT SIGNATURE Chad Wagner Contact Refused Refusal Reason:N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:03/03/2023 @ 16:13 QUESTIONS AMOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 03/03/2023 @ 16:13 Page 5 of 5